Yarı-rijit Çelik Kiriş-kolon Birleşimlerinin Yapı Davranışına Olan Etkileri

dc.contributor.advisor Yardımcı, Nesrin tr_TR
dc.contributor.author Akbaş, Tunç Tibet tr_TR
dc.contributor.department Yapı Mühendisliği tr_TR
dc.contributor.department Structural Engineering en_US
dc.date 2005 tr_TR
dc.date.accessioned 2015-12-01T13:54:53Z
dc.date.available 2015-12-01T13:54:53Z
dc.description Tez (Yüksek Lisans) -- İstanbul Teknik Üniversitesi, Fen Bilimleri Enstitüsü, 2005 tr_TR
dc.description Thesis (M.Sc.) -- İstanbul Technical University, Institute of Science and Technology, 2005 en_US
dc.description.abstract Depreme dayanıklı çelik yapı tasarımında yapının malzeme, geometri gibi temel özelliklerinin yanında kolon-kiriş birleşim davranışının da dikkate alınması gereklidir. Geleneksel çelik yapı hesaplarında kolon-kiriş birleşimleri rijit veya mafsallı olarak kabul edilmekte ve bu iki sınır durum arasındaki birleşim davranışı göz önüne alınmamaktadır. Rijit olarak tasarlanan kiriş-kolon birleşimlerinde birleşim noktasını oluşturan elemanların eksenleri arasında rölatif bir dönmenin olmadığı kabul edilir. Dolayısıyla mevcut yük altında oluşan eğilme momenti, elemanlarca, rijitlikleriyle orantılı olarak paylaşılır. Mafsallı olarak tasarlanan bir düğüm noktasında ise kolona bağlanan kiriş moment aktarmamakta ve uçlarından dönebilmektedir. Yapılar projelendirilirken düğüm noktalarını mafsallı veya rijit olarak tasarlamak mutlak ki bir çok hesap kolaylığını beraberinde getirmektedir. Ancak son yıllarda yapılan deneysel çalışmalar, kolon-kiriş birleşim noktalarının yarı-rijit olarak ele alınmasının daha gerçekçi sonuçlar verdiğini ortaya koymuştur. Bu çalışmanın amacı; yıllardan beri kavramsal olarak bilinmesine rağmen, deneysel sonuçların yetersizliği ve uzun hesap işlemlerinden dolayı ihmal edilen yarı-rijit birleşimlerin, geleneksel yöntem olan rijit ve mafsallı birleşimlerle karşılaştırılması ve sonuçların irdelenmesidir. tr_TR
dc.description.abstract In earthquake resistant design; except the general properties such as material and geometry, beam to column connections should also be taken into consideration. In traditional steel structure analyses, beam to column connections accepting in two categories; rigid and pinned, and the behavior between these situations are not considering. In beam to column connections which is designed as rigid, it is assumed that there is not any relative rotation between the axis of the elements forming the connections, thus the bending moment under the existing load, will be shared by the ratios of the elements rigidities. On the other hand, in beam to column connections which is designed as pinned, is assumed that the beam does not transfer the bending moment and will rotate on it’s ends. While designing the constructions, assuming that the joints as rigid or pinned, will certainly make the calculations easier. However experimental results show that in analyses by taking beam to column connections into consideration as semi-rigid gives more reliable results. The objective of this thesis is to compare the traditional rigid and pinned connections with the semi-rigid connections, which have been known and neglecting by many years because of the inadequacy of the experimental results and their complex calculation methods. en_US
dc.description.degree Yüksek Lisans tr_TR
dc.description.degree M.Sc. en_US
dc.identifier.uri http://hdl.handle.net/11527/10856
dc.publisher Fen Bilimleri Enstitüsü tr_TR
dc.publisher Institute of Science and Technology en_US
dc.rights İTÜ tezleri telif hakkı ile korunmaktadır. Bunlar, bu kaynak üzerinden herhangi bir amaçla görüntülenebilir, ancak yazılı izin alınmadan herhangi bir biçimde yeniden oluşturulması veya dağıtılması yasaklanmıştır. tr_TR
dc.rights İTÜ theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. en_US
dc.subject Yarı-Rijit tr_TR
dc.subject Kiriş-Kolon Birleşimi tr_TR
dc.subject Moment ve Dönme Kapasitesi tr_TR
dc.subject Semi-Rigid en_US
dc.subject Beam to Column Connections en_US
dc.subject Moment and Rotation Capacities en_US
dc.title Yarı-rijit Çelik Kiriş-kolon Birleşimlerinin Yapı Davranışına Olan Etkileri tr_TR
dc.title.alternative The Effects Of The Semi-rigid Beam To Column Connections Over The Frame Behaviour In Steel Structures en_US
dc.type Master Thesis en_US
Dosyalar
Orijinal seri
Şimdi gösteriliyor 1 - 1 / 1
thumbnail.default.alt
Ad:
3258.pdf
Boyut:
6 MB
Format:
Adobe Portable Document Format
Açıklama
Lisanslı seri
Şimdi gösteriliyor 1 - 1 / 1
thumbnail.default.placeholder
Ad:
license.txt
Boyut:
3.14 KB
Format:
Plain Text
Açıklama