Perde Ve Çerçevelerden Oluşan On İki Katlı Bir Betonarme Yapının Performansının Belirlenmesi
Perde Ve Çerçevelerden Oluşan On İki Katlı Bir Betonarme Yapının Performansının Belirlenmesi
dc.contributor.advisor | Gündüz, Necmettin | tr_TR |
dc.contributor.author | Şendağ, İzgi | tr_TR |
dc.contributor.department | Yapı Mühendisliği | tr_TR |
dc.contributor.department | Structural Engineering | en_US |
dc.date | 2010 | tr_TR |
dc.date.accessioned | 2010-11-02 | tr_TR |
dc.date.accessioned | 2015-07-03T11:27:13Z | |
dc.date.available | 2015-07-03T11:27:13Z | |
dc.date.issued | 2011-06-14 | tr_TR |
dc.description | Tez (Yüksek Lisans) -- İstanbul Teknik Üniversitesi, Fen Bilimleri Enstitüsü, 2010 | tr_TR |
dc.description | Thesis (M.Sc.) -- İstanbul Technical University, Institute of Science and Technology, 2010 | en_US |
dc.description.abstract | Bu çalışmada, Deprem Bölgelerinde Yapılacak Binalar Hakkındaki Yönetmelik kapsamında tasarımı yapılmış perde ve çerçeve taşıyıcı sisteme sahip bir betonarme yapının performans düzeyi doğrusal ve doğrusal olmayan hesap yöntemleri kullanılarak belirlenmiştir. Performans düzeyi belirlenirken doğrusal hesap yöntemlerinden mod birleştirme yöntemi, doğrusal olmayan hesap yöntemlerinden artımsal eşdeğer deprem yükü yöntemi kullanılmıştır. Analiz sırasında yapılan yaklaşımların sonuçlara etkisini incelemek için performans analizi iki ayrı sonlu eleman analiz programı kullanılarak yapılmıştır. Artımsal eşdeğer deprem yükü yönteminin uygulandığı iki farklı analiz programının sonuçları karşılaştırıldığında oldukça uygun sonuçlar elde edilmiştir. Doğrusal elastik yöntem ile performans değerlendirilmesi sonucunda artımsal eşdeğer deprem yükü yöntemine göre doğrusal elastik yöntem ile daha güvenli çözüm sonuçları elde edildiği görülmektedir. | tr_TR |
dc.description.abstract | In this study, the seismic performance of a reinforced concrete structure with concrete walls and frame structural system which has been implemented by the Turkish Seismic Code (DBYBHY’07) is determined according to linear and nonlinear analysis methods. The mode superposition method from the linear analysis methods and the incremental equivalent earthquake load method from the nonlinear analysis were used in order to determine the seismic performances. The performance analysis were carried out by two different types of finite elements analysis softwares in order to study the effects of the approximations to the conclusion prescribed in the performance analysis. The results were considerably reasonable in comparing the above mentioned two different analysis softwares where incremental equivalent earthquake load method is applied. As a result of the seismic performance evaluation, it’s seen that the linear elastic analysis method has given more reliable results compared to the incremental equivalent earthquake load method. | en_US |
dc.description.degree | Yüksek Lisans | tr_TR |
dc.description.degree | M.Sc. | en_US |
dc.identifier.uri | http://hdl.handle.net/11527/6567 | |
dc.publisher | Fen Bilimleri Enstitüsü | tr_TR |
dc.publisher | Institute of Science and Technology | en_US |
dc.rights | İTÜ tezleri telif hakkı ile korunmaktadır. Bunlar, bu kaynak üzerinden herhangi bir amaçla görüntülenebilir, ancak yazılı izin alınmadan herhangi bir biçimde yeniden oluşturulması veya dağıtılması yasaklanmıştır. | tr_TR |
dc.rights | İTÜ theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. | en_US |
dc.subject | Artımsal eşdeğer deprem yükü | tr_TR |
dc.subject | mod birleştirme | tr_TR |
dc.subject | Incremental Equivalent Earthquake Load Method | en_US |
dc.subject | Mode Superposition | en_US |
dc.title | Perde Ve Çerçevelerden Oluşan On İki Katlı Bir Betonarme Yapının Performansının Belirlenmesi | tr_TR |
dc.title.alternative | Seismic Performance Assessment Of A 12 Storey Reinforced Concrete Shear Wall-frame Structure | en_US |
dc.type | masterThesis | en_US |