Küçük Hidroelektrik Santraller Ve Dere Yatağında Bırakılması Gereken Can Suyu Miktarı
Küçük Hidroelektrik Santraller Ve Dere Yatağında Bırakılması Gereken Can Suyu Miktarı
dc.contributor.advisor | Uyumaz, Y. Ali | tr_TR |
dc.contributor.author | Çimenci, Veysel | tr_TR |
dc.contributor.authorID | 415908 | tr_TR |
dc.contributor.department | Hidrolik ve Su Kaynakları Mühendisliği | tr_TR |
dc.contributor.department | Hydraulics and Water Resources Engineerin | en_US |
dc.date | 2011 | tr_TR |
dc.date.accessioned | 2011-10-19 | tr_TR |
dc.date.accessioned | 2015-07-15T13:41:31Z | |
dc.date.available | 2015-07-15T13:41:31Z | |
dc.date.issued | 2011-11-01 | tr_TR |
dc.description | Tez (Yüksek Lisans) -- İstanbul Teknik Üniversitesi, Fen Bilimleri Enstitüsü, 2011 | tr_TR |
dc.description | Thesis (M.Sc.) -- İstanbul Technical University, Institute of Science and Technology, 2011 | en_US |
dc.description.abstract | Nehirler üzerinde yapılan su yapıları su miktarı, kalitesi ve dolayısıyla da su ekosistemi üzerinde etkiler oluşturmaktadır. Bu nedenle mansaptaki su ekosisteminin korunması için de gerekli düşük akımın (can suyu) belirlenmesi önemli bir problem olarak ortaya çıkmaktadır. Hidrolojide düşük akım hesabı; içme ve sulama suyu temininde, hidroelektrik santrallerden verilecek minimum etek suyu hesabında, su kirliliğine yönelik çalışmalarda ve nehirlerdeki su ekosistemin devamlılığı için gerekli su miktarının belirlenmesinde kullanılmaktadır. Bu çalışmada nehirlerdeki ekolojik dengenin korunması için hidroelektrik santrallerden nehir yatağına bırakılacak minimum debinin belirlenmesi konusu incelenmiştir. Konuyla ilgili olarak literatürde yer alan çeşitli yöntemler değerlendirilmiş ve bu yöntemlerin dünya ülkelerinde kullanımı incelenmiştir. Ülkemizde yaşanan problemler, dünya ülkelerindeki eğilimler ile birlikte değerlendirilerek, bu problemlerin çözülebilmesi adına çeşitli öneriler sunulmuştur. | tr_TR |
dc.description.abstract | Structures built on rivers, have effects on water amount, water quality and consequently on water ecosystem. In this reason, determination of required environmental flow to protect water ecosystem in river mouth constitutes a significant problem. The calculation of low flow in science of Hydrology, is used for procurement of potable and irrigation water, calculation of downstream left from hydroelectric power plant, studies of water pollution and determination water amount needed for permanence of water ecosystem on rivers. In this study, determination of minimum flow rate left to river bed from hydroelectric power plant in order to protect ecological balance on rivers was investigated. Various methodologies according to the subject in literature, were evaluated and utilization of these methodologies in different countries was studied. The problems in our country, were evaluated with tendencies in different countries and various solutions were presented for these problems. | en_US |
dc.description.degree | Yüksek Lisans | tr_TR |
dc.description.degree | M.Sc. | en_US |
dc.identifier.uri | http://hdl.handle.net/11527/7967 | |
dc.publisher | Fen Bilimleri Enstitüsü | tr_TR |
dc.publisher | Institute of Science and Technology | en_US |
dc.rights | İTÜ tezleri telif hakkı ile korunmaktadır. Bunlar, bu kaynak üzerinden herhangi bir amaçla görüntülenebilir, ancak yazılı izin alınmadan herhangi bir biçimde yeniden oluşturulması veya dağıtılması yasaklanmıştır. | tr_TR |
dc.rights | İTÜ theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. | en_US |
dc.subject | hidroelektrik santraller | tr_TR |
dc.subject | can suyu miktarı | tr_TR |
dc.subject | çevresel akış miktarı | tr_TR |
dc.subject | hydroelectric power plant | en_US |
dc.subject | environmental flow | en_US |
dc.subject | minimum flow | en_US |
dc.title | Küçük Hidroelektrik Santraller Ve Dere Yatağında Bırakılması Gereken Can Suyu Miktarı | tr_TR |
dc.title.alternative | Hydroelectric Power Plant And Environmental Flow Amount Needed For Stream Bed | en_US |
dc.type | Master Thesis | en_US |