Damla Sulaması Sistemlerinde G Faktörü Kullanılarak Basınç Değişimlerinin Hesaplanması

dc.contributor.advisor Kabdaşlı, Sedat tr_TR
dc.contributor.author Saka, Yakup tr_TR
dc.contributor.department Su Mühendisliği tr_TR
dc.contributor.department Hydraulic Engineering en_US
dc.date 2001 tr_TR
dc.date.accessioned 2015-12-16T09:52:05Z
dc.date.available 2015-12-16T09:52:05Z
dc.description Tez (Yüksek Lisans) -- İstanbul Teknik Üniversitesi, Fen Bilimleri Enstitüsü, 2001 tr_TR
dc.description Thesis (M.Sc.) -- İstanbul Technical University, Institute of Science and Technology, 2001 en_US
dc.description.abstract Bu çalışmada, damla sulamasında kullanılan borularda damlatıcı debilerinin boru boyunca değişimi deneysel olarak elde edilmiş olup, değişimin kaynak yayınlarda verildiği şekilde boru boyunun ilk üçte bir bölümünde büyük olduğu gösterilmiştir. Damlatıcı debilerinin boru boyunca değişimi, damlatıcı tipine de bağlı olmakla birlikte düşük işletme basınçlarında daha az; artan işletme basınçlarında ise daha büyüktür. Basınç değişiminin hesaplanmasında kullanılan Christiansen azaltma faktörü, F, basıncın boru boyunca değişimini hiçbir şekilde karakterize etmemektedir. Kullanılan üç tip damlatıcıda da özellikle lateralin ikinci ve üçüncü çeyreklerinde %100’ün üzerinde sapmalar ortaya çıkmaktadır. G faktörü ile basınç değişikliklerinin hesaplanmasının mümkün olduğu gösterilmiştir. Yapılan deneysel çalışmada her üç tip damlatıcı için G faktörü ile basınçların boru boyunca değişiminin hesaplanan değerleri, gidiş olarak ölçümlerle uyum sağlamıştır. Yine G faktörü ile hesaplarda damlatıcıların gruplar haline getirilerek hesapların azaltılmasının mümkün olduğu ve bunun sonuçlarda bir değişiklik yaratmadığı da gösterilmiştir. G faktörünün kullanılmasında boru boyundan ve damlatıcı tipinden bağımsız bir yöntem ortaya konulmuştur. Bu yöntemin ana parametresi olan G/Gmax boyutsuz G faktörünün Li/L boyutsuz boru boyu ile değişiminin damlatıcı tipinden bağımsız gösterilmiştir. Önerilen hesap yönteminin geçerliliğini göstermek amacıyla yapılan uygulama çalışmasında hesaplanan ve ölçülen basınç değerlerinin neredeyse üst üste düştüğü görülmüştür. tr_TR
dc.description.abstract In this study, the variation of emitter discharges along the pipe in drip irrigation laterals were obtained experimentally and it is shown high variation in the first 1/3 of pipe length as given in the literature of drip irrigation. The variation of emitter discharges along the pipe, which also depends on the type of emitter, under low operation pressures is less than that under increasing operation pressures. Christiansen’s factor F which is used for calculating the variation of pressure never characterizes the variation of pressure along the pipe. There were deviations higher than 100% especially in the second and third quarters of laterals for each type of emitter in tests. It is shown that it is possible to calculate the variation of pressure along the pipe by means of factor G proposed by Anwar (1999). For three type of emitters in tests, the values of the variation of pressure calculated by using factor G is compatible with tha values obtained from tests. In calculating by factor G, it was shown that it is possible to lower the calculations by rearranging emitters in groups and it didn’t change the results. In the use of factor G, a method is proposed that is independent from lateral length and the type of emitter. In this method, it is shown that the variation of main parameter G/Gmax (nondimensional factor G) with Li/L (nondimensional lateral length) is independent from the type of emitter. In order to prove the validity of the proposed calculation method, it is shown by an application that the values obtained from calculations were almost the same as the values obtained from tests. en_US
dc.description.degree Yüksek Lisans tr_TR
dc.description.degree M.Sc. en_US
dc.identifier.uri http://hdl.handle.net/11527/11503
dc.publisher Fen Bilimleri Enstitüsü tr_TR
dc.publisher Institute of Science And Technology en_US
dc.rights İTÜ tezleri telif hakkı ile korunmaktadır. Bunlar, bu kaynak üzerinden herhangi bir amaçla görüntülenebilir, ancak yazılı izin alınmadan herhangi bir biçimde yeniden oluşturulması veya dağıtılması yasaklanmıştır. tr_TR
dc.rights İTÜ theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. en_US
dc.subject Damla sulaması tr_TR
dc.subject Basınç değişimi tr_TR
dc.subject G faktörü tr_TR
dc.subject F faktörü tr_TR
dc.subject Drip irrigation en_US
dc.subject Variation of pressure en_US
dc.subject Factor G en_US
dc.subject Factor F en_US
dc.title Damla Sulaması Sistemlerinde G Faktörü Kullanılarak Basınç Değişimlerinin Hesaplanması tr_TR
dc.title.alternative Calculating Of The Variations Of Pressure By Using G-factor In Drip Irrigation Systems en_US
dc.type Thesis en_US
dc.type Tez tr_TR
Dosyalar
Orijinal seri
Şimdi gösteriliyor 1 - 1 / 1
thumbnail.default.alt
Ad:
462.pdf
Boyut:
15 MB
Format:
Adobe Portable Document Format
Açıklama
Lisanslı seri
Şimdi gösteriliyor 1 - 1 / 1
thumbnail.default.placeholder
Ad:
license.txt
Boyut:
3.14 KB
Format:
Plain Text
Açıklama