Dış Gürültü Düzeyine Ve Mekan Fonksiyonuna Bağlı Olarak Konut Kabuklarında İzin Verilebilecek En Büyük Pencere Alanı Oranları Ve Malzemelerinin Belirlenmesi

dc.contributor.advisor Kurra, Selma tr_TR
dc.contributor.author Saral, Z. Fulya tr_TR
dc.contributor.authorID 75321 tr_TR
dc.contributor.department Mimarlık tr_TR
dc.contributor.department Architecture en_US
dc.date 1998 tr_TR
dc.date.accessioned 2018-12-10T08:35:16Z
dc.date.available 2018-12-10T08:35:16Z
dc.date.issued 1998 tr_TR
dc.description Tez (Yüksek Lisans) -- İstanbul Teknik Üniversitesi, Fen Bilimleri Enstitüsü, 1998 tr_TR
dc.description Thesis (M.Sc.) -- İstanbul Technical University, Institute of Science and Technology, 1998 en_US
dc.description.abstract Tablo B.4 Düşey Delikli Tuğla 0. 145 için Uygulanabilir En Büyük Pencere Oranlan 240 Tablo B.5 Yapı Blok 0. 19 için Uygulanabilir En Büyük Pencere Oranlan 241 Tablo B.6 Yatay Delikli Tuğla 0. 19 için Uygulanabilir En Büyük Pencere Oranlan 242 Tablo B.7 Düşey Delikli Tuğla 0. 1 9 için Uygulanabilir En Büyük Pencere Oranlan 243 Tablo B.8 Deliksiz Tuğla 0. 19 için Uygulanabilir En Büyük Pencere Oranlan 244 Tablo C.l Ytong 0.20 için Örnek Uygulamanın Çözümü 245 Tablo C.2 Ytong 0.25 için Örnek Uygulamanın Çözümü 246 Tablo C.3 Yatay Delikli Tuğla 0.135 için Örnek Uygulamanın Çözümü 247 Tablo C.4 Düşey Delikli Tuğla 0. 1 45 için Örnek Uygulamanın Çözümü 248 Tablo C.5 Yapı Blok 0.19 için Örnek Uygulamanın Çözümü 249 Tablo C.6 Yatay Delikli Tuğla 0.19 için Örnek Uygulamanın Çözümü 250 Tablo C.7 Düşey Delikli Tuğla 0. 19 için Örnek Uygulamanın Çözümü 25 1 Tablo C. 8 Deliksiz Tuğla 0.19 için Örnek Uygulamanın Çözümü 252 Tablo D.l Şekil A. 1,2,3,4,5,6,7,8 için Kabuk Alternatif Numaralan Listesi 253 Tablo D.2 Şekil A. 1,2,3,4,5,6,7,8 için Kabuk Alternatif Numaralan Listesi 254 tr_TR
dc.description.abstract Table 1 Required insulation values depending on outdoor noise levels in Leq, dBA Bedrooms (NCB 25) The estimations are made for: a) 5 x 3 m Total wall area representing a typical room facade. b) The wall types are shown in table 2 XX Tablo B.4 Düşey Delikli Tuğla 0. 145 için Uygulanabilir En Büyük Pencere Oranlan 240 Tablo B.5 Yapı Blok 0. 19 için Uygulanabilir En Büyük Pencere Oranlan 241 Tablo B.6 Yatay Delikli Tuğla 0. 19 için Uygulanabilir En Büyük Pencere Oranlan 242 Tablo B.7 Düşey Delikli Tuğla 0. 1 9 için Uygulanabilir En Büyük Pencere Oranlan 243 Tablo B.8 Deliksiz Tuğla 0. 19 için Uygulanabilir En Büyük Pencere Oranlan 244 Tablo C.l Ytong 0.20 için Örnek Uygulamanın Çözümü 245 Tablo C.2 Ytong 0.25 için Örnek Uygulamanın Çözümü 246 Tablo C.3 Yatay Delikli Tuğla 0.135 için Örnek Uygulamanın Çözümü 247 Tablo C.4 Düşey Delikli Tuğla 0. 1 45 için Örnek Uygulamanın Çözümü 248 Tablo C.5 Yapı Blok 0.19 için Örnek Uygulamanın Çözümü 249 Tablo C.6 Yatay Delikli Tuğla 0.19 için Örnek Uygulamanın Çözümü 250 Tablo C.7 Düşey Delikli Tuğla 0. 19 için Örnek Uygulamanın Çözümü 25 1 Tablo C. 8 Deliksiz Tuğla 0.19 için Örnek Uygulamanın Çözümü 252 Tablo D.l Şekil A. 1,2,3,4,5,6,7,8 için Kabuk Alternatif Numaralan Listesi 253 Tablo D.2 Şekil A. 1,2,3,4,5,6,7,8 için Kabuk Alternatif Numaralan Listesi 254 XVU Table 1 Required insulation values depending on outdoor noise levels in Leq, dBA Bedrooms (NCB 25) The estimations are made for: a) 5 x 3 m Total wall area representing a typical room facade. b) The wall types are shown in table 2 XX c) The glazing types are shown in table 3 Table 2 Wall types used in the calculations Table 3 Glazing types used in the calculations L : Lamina glazing : Special glazing xxi In the comparison, the sound reduction is represented by single number rating given by ISO 717/1:1996 for airborne sound and it is used instead of frequency dependent values. This is named weighted reduction (Rw) as it is shown below: 250 500 1000 2 000 4 000 Frequency, Hz Weighted Reduction (Rw) (ISO 717/1 : 1996) The value of Rw changes according to the two types of noise: pink noise and traffic noise. The values given in the above tables are taken as the adjusted Rw values regarding to the traffic noise. In this study, Rw values directly given for traffic noise are used. However, these should be corrected for the flanking transmission by subtracting 2 dB from the calculated Rw values, as suggested in the European Standard. The sound reductions were estimated by using the following formulas: R=101og(l/x) R : Sound reduction, dB x : Sound Transmission coefficient, dimensionless T tot ( ^glazing x ^glazing + X wall x S wau) / 2*S x tol : Sound Transmission coefficient, dimensionless glazing : Glazing Sound Transmission coefficient, dimensionless en_US
dc.description.degree Yüksek Lisans tr_TR
dc.description.degree M.Sc. en_US
dc.identifier.uri http://hdl.handle.net/11527/16988
dc.language.iso tur tr_TR
dc.publisher Fen Bilimleri Enstitüsü tr_TR
dc.publisher Institute of Science and Technology en_US
dc.rights Kurumsal arşive yüklenen tüm eserler telif hakkı ile korunmaktadır. Bunlar, bu kaynak üzerinden herhangi bir amaçla görüntülenebilir, ancak yazılı izin alınmadan herhangi bir biçimde yeniden oluşturulması veya dağıtılması yasaklanmıştır. tr_TR
dc.rights All works uploaded to the institutional repository are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. en_US
dc.subject Malzeme belirleme tr_TR
dc.subject Pencereler tr_TR
dc.subject Material determination en_US
dc.subject Windows en_US
dc.title Dış Gürültü Düzeyine Ve Mekan Fonksiyonuna Bağlı Olarak Konut Kabuklarında İzin Verilebilecek En Büyük Pencere Alanı Oranları Ve Malzemelerinin Belirlenmesi tr_TR
dc.type Master Thesis en_US
Dosyalar
Orijinal seri
Şimdi gösteriliyor 1 - 1 / 1
thumbnail.default.alt
Ad:
75321.pdf
Boyut:
15.79 MB
Format:
Adobe Portable Document Format
Açıklama
Lisanslı seri
Şimdi gösteriliyor 1 - 1 / 1
thumbnail.default.placeholder
Ad:
license.txt
Boyut:
3.16 KB
Format:
Plain Text
Açıklama