No-frost Derin Dondurucu İçindeki Sıcaklık Dağılımı Ve Hava Akışının İncelenmesi

dc.contributor.advisor Nikbay, Melike tr_TR
dc.contributor.author Pakdil, Mustafa Barış tr_TR
dc.contributor.authorID 409870 tr_TR
dc.contributor.department Uçak Mühendisliği tr_TR
dc.contributor.department Aircraft Engineering en_US
dc.date 2011 tr_TR
dc.date.accessioned 2011-08-03 tr_TR
dc.date.accessioned 2015-06-10T14:46:30Z
dc.date.available 2015-06-10T14:46:30Z
dc.date.issued 2013-01-06 tr_TR
dc.description Tez (Yüksek Lisans) -- İstanbul Teknik Üniversitesi, Fen Bilimleri Enstitüsü, 2011 tr_TR
dc.description Thesis (M.Sc.) -- İstanbul Technical University, Institute of Science and Technology, 2011 en_US
dc.description.abstract No-frost buzdolaplarında kabin içerisindeki sıcaklık dağılımı enerji tüketimi açısından önemlidir. Yiyecekleri temsil eden ölçüm paketleri ile yapılan deneylerde paketler arasındaki farkın en aza indirgenmesinin enerji tüketimini iyileştirdiği görülmektedir. Bu sebeple no-frost dolapların özelliği olan hava sağlama sistemi üzerinde değişiklikler yaparak kabin içindeki sıcaklıklara etki etmek mümkündür. Bu çalışmayı literatür çalışmalarından farklı kılan özellik hava sağlama sisteminin kapalı çevrim olmasıdır. Literatürde varolan çalışmalarda debi değeri sınır şartı olarak verilmektedir. Hava sağlama sisteminin tamamının modellendiği bu çalışmada ise sistem içinde debi incelemesi yapmak mümkün olmuştur. Daha sonra bu sonuçlar deneysel çalışmalarla karşılaştırılmıştır. Bulunan sonuçlar birbirlerine çok yakın olduğu için yapılan diğer analizlerin de doğruluğu kabul edilmiştir. Çalışmada farklı üfleme delikleri konfigürasyonları kullanılarak da incelemeler yapılmıştır. Bu analizlerin sonucunda toplam debi ve her bir üfleme deliğinden çıkan debi değerleri verilmiştir. Debinin yanında kabin içinde sıcaklık dağılımları ve deneysel çalışmalarla uyumluluğu gösteren ölçüm paketlerinin sıcaklık dağılımları verilmiştir. Yapılan deneyler ve bunları destekleyen analizler doğrultusunda kabin içinde sıcaklıklar duvarlara yaklaştıkça artmaktadır. En soğuk paketler alt bölgeye yakın olup en sıcak paketler üst bölgelerde çıkmaktadır. En yüksek üfleme debileri ise hava sağlama sistemi boyunca hava akışı doğrultusunda bulunan alt ve üst üfleme deliklerinde görülmektedir. Bununla birlikte, hava sağlama kanalı üzerinde ve normali kanal içindeki hava akışına dik doğrultuda olan üfleme delikleri kısıldıkça, toplam debinin arttığı, alt ve üst delikler kısıldığında ise toplam debinin azaldığı görülmüştür. tr_TR
dc.description.abstract In a no-frost refrigerator, homogenity of the cabinet temperature distribution is important for reducing energy consumption. Minimizing the temperature differences between the loaded packages (which represent foods) provides a beter energy comsumption. Reducing the energy consumption is possible by changing the air supply system characteristics of a no-frost refrigerator. What makes this study different from similar literature studies, is that the airsupply system is modelled as a closed-loop system while former studies mass flow rates are given as boundary conditions. However, in this study, the air supply system is completely modeled so that mass flow rates could be investigated numerically as well. Furthermore the CFD analysis were validated with experimental studies. Computational analysis for different air supply hole configurations were also used in this study. As a result of the analysis for each hole and for total air supply mass flow rates are computed and the temperature distribution in the cabinet are visualised. And the results are validated with the experimental studies. Validated from the computational analysis and the experimental studies, it is seen that temperature values increase in the neighbourhoods of the walls of the cabinet. The coolest packages are found to be in the bottom regions while the warmest ones are in the upper regions. The highest mass flow rates are at the holes which are through the airflow while the lowest rates are found at the holes which are perpendicular to the airflow direction in the airsupply system duct. Another observation in the study is that, decreasing the total area of the holes which are perpendicular to the airflow direction in the duct increases the total mass flow rate. In the other hand, decreasing the total area of the uppest and lowest holes, whose normal direction is same as the airflow direction in the duct, decreases total mass flow rate also decreases. en_US
dc.description.degree Yüksek Lisans en_US
dc.description.degree M.Sc. tr_TR
dc.identifier.uri http://hdl.handle.net/11527/4806
dc.publisher Fen Bilimleri Enstitüsü tr_TR
dc.publisher Institute of Science and Technology en_US
dc.rights İTÜ tezleri telif hakkı ile korunmaktadır. Bunlar, bu kaynak üzerinden herhangi bir amaçla görüntülenebilir, ancak yazılı izin alınmadan herhangi bir biçimde yeniden oluşturulması veya dağıtılması yasaklanmıştır. tr_TR
dc.subject hesaplamalı akışkanlar dinamiği tr_TR
dc.subject buzdolabı tr_TR
dc.subject sıcaklık dağılımı tr_TR
dc.subject hava akışı tr_TR
dc.subject computational ffluid dynamics en_US
dc.subject refrigerator en_US
dc.subject temperature distribution en_US
dc.subject air flow en_US
dc.title No-frost Derin Dondurucu İçindeki Sıcaklık Dağılımı Ve Hava Akışının İncelenmesi tr_TR
dc.title.alternative Investigation Of Temperature Distribution And Air Fow In A No-frost Freezer en_US
dc.type Master Thesis en_US
Dosyalar
Orijinal seri
Şimdi gösteriliyor 1 - 1 / 1
thumbnail.default.alt
Ad:
12006.pdf
Boyut:
2.21 MB
Format:
Adobe Portable Document Format
Açıklama
Lisanslı seri
Şimdi gösteriliyor 1 - 1 / 1
thumbnail.default.placeholder
Ad:
license.txt
Boyut:
3.16 KB
Format:
Plain Text
Açıklama