Doğrudan Katı Örneklemeli Yüksek Çözünürlüklü Sürekli Işık Kaynaklı Atomik Absorpsiyon Spektrometresi İle Camlarda Kurşun Analizi

dc.contributor.advisor Özcan, Mustafa tr_TR
dc.contributor.author Demir, Seda tr_TR
dc.contributor.authorID 406418 tr_TR
dc.contributor.department Kimyagerlik tr_TR
dc.contributor.department Chemistry en_US
dc.date 2011 tr_TR
dc.date.accessioned 2011-07-11 tr_TR
dc.date.accessioned 2015-07-13T10:14:58Z
dc.date.available 2015-07-13T10:14:58Z
dc.date.issued 2011-07-14 tr_TR
dc.description Tez (Yüksek Lisans) -- İstanbul Teknik Üniversitesi, Fen Bilimleri Enstitüsü, 2011 tr_TR
dc.description Thesis (M.Sc.) -- İstanbul Technical University, Institute of Science and Technology, 2011 en_US
dc.description.abstract Günlük hayatta çok sıkça kullanılan cam, amorf yapılı, genellikle kristalleşmeden katılaşan inorganik bir çözeltidir. Kimyasal formül olarak SiO2, Al2O3, CaO, MgO, Na2O, PbO, B2O3 gibi çeşitli oksitlerin belirli oranlarda karışımıdır. Camların özellikleri bileşimlerine göre farklılıklar gösterir. Borosilikat camları ısıya karşı dayanıklı iken PbO camın kırılma indisini arttır ve kristal camlarda ışığın renklerine ayrılmasını sağlar. Bazı metal oksitleri cama renk verir. Renklendirici oksitler karıştırılarak farklı renk ve tonlar elde dilebilir. Örneğin demir oksit yeşil veya sarımsı renk verirken manganez oksit mor renk sağlar. Atomik absorpsiyon spektrometre (AAS) ile element analizlerinde örnekler bir çözünürleştirme işlemi sonrasında cihaza sıvı olarak verilir. Ancak son yıllarda doğrudan katı örneklemeli Atomik Absorpsiyon Spektrometresi de geliştirilmiştir. Katı örneklemeli AAS örnekleri çözünürleştirmeye gerek duymadan örneğin cihaza doğrudan katı olarak verilmesine uygun yeni bir tekniktir. Böylece örneğin kirlenme riski ve analitik hatalar azalmakta, analiz süresi kısalmaktadır. Cam oldukça zor çözünebilen, çözme işlemi için kuvvetli ve zararlı asitlerin kullanılmasını gerektiren bir maddedir. Bu çalışmada camda element analizlerinde, mevcut analiz yöntemlerine alternatif olarak, doğrudan katı örneklemeli AAS’nin kullanımı araştırılarak yeni bir yöntem geliştirilmiştir. Bu amaçla, element içeriği bilinen NIST SRM 612 cam standart referans maddesi kullanarak Doğrudan katı örneklemeli AAS de Pb elementi analizleri için uygun dalga boyu, uygulanan sıcaklık programı-ölçüm süresi, numune tartım aralığı, modifier kullanımı gibi çeşitli aletsel parametreler belirlenerek, sıvı standartlara kalibrasyon grafiği gibi sonuçların doğruluğuna etki eden faktörler araştırılmıştır. Yöntem geliştirilmesi sonrası iki adet cam örneğinde Pb konsantrasyonu Doğrudan katı örneklemeli AAS ile tayin edilerek, sonuçlar cam örneklerinin çözünürleştirilmesi sonucu okunan Pb konsantrasyonları ile karşılaştırılmıştır. tr_TR
dc.description.abstract Glass is used more frequently in daily life, and it is an inorganic amorphous solution. It is a chemical mixture of some oxides like SiO2, Al2O3, CaO, MgO, Na2O , PbO, B2O3. Glasses differ from each other depending on their components. Glasses containing borosilicate are resistant to heat. PbO gives high refractive index and provide the diffraction of light in crystals. Some metal oxides give colors. Different colors can be obtained by mixing these oxides. For example iron oxide gives green-yellow color and manganese oxide gives violet. In the analysis of the elements by AAS, samples generally must be in a solution but Direct Solid Sampling Atomic absorption spectrometer (SS-GFAAS) has developed recently, and samples can be introduced as a solid without dissolving in to graphite furnace directly in this technique. Thus dissolving step of the sample is avoided, the contamination risk, errors and analysis time are reduced. In this study a new method for the determination of Pb in glass samples with solid sampling atomic absorption spectrometry was devoloped. For this purpose different experimental parameters such as sample weight which introduced to SS-GFAAS, pyrolysis temperatures, using modifier, using liquid Standard calibration and also wavelength were investigated in the analysis of Pb in NIST SRM 612 Glass Reference Materials by SS-GFAAS and the optimum conditions were determined. After development the method, 2 glass samples were analyzed and results are compared with the dissolved glass samples’ Pb concentrations. en_US
dc.description.degree Yüksek Lisans tr_TR
dc.description.degree M.Sc. en_US
dc.identifier.uri http://hdl.handle.net/11527/7373
dc.publisher Fen Bilimleri Enstitüsü tr_TR
dc.publisher Institute of Science and Technology en_US
dc.rights İTÜ tezleri telif hakkı ile korunmaktadır. Bunlar, bu kaynak üzerinden herhangi bir amaçla görüntülenebilir, ancak yazılı izin alınmadan herhangi bir biçimde yeniden oluşturulması veya dağıtılması yasaklanmıştır. tr_TR
dc.rights İTÜ theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission en_US
dc.subject Atomik absorpsiyon spektrometre tr_TR
dc.subject doğrudan katı örneklemeli yöntem tr_TR
dc.subject Atomic absorption spectrometer en_US
dc.subject direct solid sampling method en_US
dc.title Doğrudan Katı Örneklemeli Yüksek Çözünürlüklü Sürekli Işık Kaynaklı Atomik Absorpsiyon Spektrometresi İle Camlarda Kurşun Analizi tr_TR
dc.title.alternative Lead Analysis In Glass By Direct Solid Sampling High Resolution Continuous Source Atomic Absorption Spectrometer en_US
dc.type Master Thesis en_US
Dosyalar
Orijinal seri
Şimdi gösteriliyor 1 - 1 / 1
thumbnail.default.alt
Ad:
11913.pdf
Boyut:
1.27 MB
Format:
Adobe Portable Document Format
Açıklama
Lisanslı seri
Şimdi gösteriliyor 1 - 1 / 1
thumbnail.default.placeholder
Ad:
license.txt
Boyut:
3.16 KB
Format:
Plain Text
Açıklama