Farklı Kolimatörlerle Orbiter Gama Kamerada Tc-99m Radyoizotopu Ve Fantom Kullanarak Lenfosintigrafi Çekimlerinin Değerlendirilmesi

dc.contributor.advisor Tuğrul, A. Beril tr_TR
dc.contributor.author Dirlik, Engin tr_TR
dc.contributor.authorID 104146 tr_TR
dc.contributor.department Nükleer Araştırmalar tr_TR
dc.contributor.department Nuclear Studies en_US
dc.date 2001 tr_TR
dc.date.accessioned 2018-12-18T13:49:44Z
dc.date.available 2018-12-18T13:49:44Z
dc.date.issued 2001-06-11 tr_TR
dc.description Tez (Yüksek Lisans) -- İstanbul Teknik Üniversitesi, Enerji Enstitüsü, 2001 tr_TR
dc.description Thesis (M.Sc.) -- İstanbul Technical University, Energy Institute, 2001 en_US
dc.description.abstract Nükleer teknikler, birçok alanda olduğu gibi tıp alanında da basan ile uygulanmaktadır. Radyoizotoplar, insan sağlığına ilişkin uygulamalarda yeni ufuklar açmıştır. Teşhis ve tedavi amaçlı olan nükleer teknik uygulamaları, radyasyonun canlı üzerinde kullanılmasından ötürü bazı sorunlar da oluşturabilmektedir. Bu sorunların başında, iyonizan radyasyonların çevre, radyasyon çalışanları ve hastaya olabilecek zararlı etkileri gelmektedir. Teşhis amaçlı uygulamalarda yaygın kullanılan tekniklerden biri gama kamera ile sintigrafi uygulamalarıdır ve bu amaçla çoğu kez Tc-99m radyoizotopundan yararlanılmaktadır. Uygulamada insanın etkilenmesine ilişkin bilgi edinilmesi, tekniğin basan ile uygulanabilmesi için elzem olan bir konudur. İnsan üzerinde deney yapmanın zorluğu nedeni ile çoğu kez fantomla çalışma tercih edilmektedir. Bu çalışmada, polimer bir fantom kullanılarak deney yapılması hedeflenmiştir. Bunun için özel bir fantom tasanmlanmıştır. Fantom üzerinde açılan deliklere Tc-99m radyoizotopu solüsyonu yerleştirilerek sintigrafisinin alınması sağlanmıştır. Lenfosintigrafide yaygın kullanımlı bir gama kamera olan Orbiter gama kamera kullanılarak ve üç farklı kolimatör ile, farklı geometrilerde çekimler yapılmıştır. Kullanılan kolimatörler; düşük enerjili genel amaçlı (LEAP) kolimatör, orta enerjili genel amaçlı (MEAP) kolimatör ve düşük enerjili yüksek rezolüsyonlu (LEHR) kolimatördür. Alman deneysel sonuçlar birbiri ile mukayeseli olarak incelenerek değerlendirilmiş ve farklı kolimatörlerin kullanımlarına ilişkin ileri bilgiler edinilmiştir. Böylelikle, lenfosintigrafi için uygun kolimatör kullanım şartlarının oluşturulması deneysel olarak beMenebilmiştir. tr_TR
dc.description.abstract Nuclear techniques are successfully applied in the medicine in addition to the other areas. Radioisotopes have opened a new vision in the applications of human health. Some problems have been forward by using radiation on the alive during the usage of diagnostic and teraphic applications. The most important one is harmful effect of the ionized radiation on environment, radiation workers and patients. Scintigraphic applications with gamma cameras are widespread applications in the diagnostic purposes and in here generally preferred Tc-99m radioisotope. Then, it should be known that, what is the effect of the radiation on the human. Generally using a phantom is preferred for the experimental studies due to hard to study on a man. In this study, using a polymere phantom is aimed for doing experiments. For this purpose, a polymere phantom with different holes, is used in the experiments. 'With different doses Tc-99m is placed in the hole, which are drilled before and then taking the syntigraphic image. It is plarmd with the different geometry by using different collimators with a Orbiter gamma camera which is widespreadly used for the lymphoscintigrapy. The collimators which are used in this study are Low Energy All Purpose (LEAP), Medium Energy All Purpose (MEAP) and Low Energy High Resolution (LEHR). Experimental results are evaluated comparatively and obtained the informations of usage of different collimators. So, it is determined that the most convenient collimator usage conditions for lymphoscintigraphy experimentally. en_US
dc.description.degree Yüksek Lisans tr_TR
dc.description.degree M.Sc. en_US
dc.identifier.uri http://hdl.handle.net/11527/17434
dc.language tur tr_TR
dc.publisher Enerji Enstitüsü tr_TR
dc.publisher Energy Institute en_US
dc.rights Kurumsal arşive yüklenen tüm eserler telif hakkı ile korunmaktadır. Bunlar, bu kaynak üzerinden herhangi bir amaçla görüntülenebilir, ancak yazılı izin alınmadan herhangi bir biçimde yeniden oluşturulması veya dağıtılması yasaklanmıştır. tr_TR
dc.rights All works uploaded to the institutional repository are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. en_US
dc.subject Nükleer tıp tr_TR
dc.subject Radyasyon tr_TR
dc.subject Sintigrafi tr_TR
dc.subject Teknesyum Tc-99m tr_TR
dc.subject Nuclear medicine en_US
dc.subject Radiation en_US
dc.subject Radioisotopes en_US
dc.subject Scintigraphy en_US
dc.subject Technetium Tc-99m en_US
dc.title Farklı Kolimatörlerle Orbiter Gama Kamerada Tc-99m Radyoizotopu Ve Fantom Kullanarak Lenfosintigrafi Çekimlerinin Değerlendirilmesi tr_TR
dc.title.alternative Evaluation Of Lymphoscintigraphy With Orbiter Gamma Camera And Different Collimators By Using Tc-99m And Phantom en_US
dc.type Master Thesis en_US
Dosyalar
Orijinal seri
Şimdi gösteriliyor 1 - 1 / 1
thumbnail.default.alt
Ad:
104146.pdf
Boyut:
21.39 MB
Format:
Adobe Portable Document Format
Açıklama
Lisanslı seri
Şimdi gösteriliyor 1 - 1 / 1
thumbnail.default.placeholder
Ad:
license.txt
Boyut:
3.14 KB
Format:
Plain Text
Açıklama