Polietilendioksitiyofen-paratolisülfonilpirol Kopolimerinin Karbonfiber Mikro Buton Elektrod Üzerinde Empedans Ve Biyosensor Davranışı
Polietilendioksitiyofen-paratolisülfonilpirol Kopolimerinin Karbonfiber Mikro Buton Elektrod Üzerinde Empedans Ve Biyosensor Davranışı
dc.contributor.advisor | Saraç, A. Sezai | tr_TR |
dc.contributor.author | Kılıç, Bilge | tr_TR |
dc.contributor.department | Polimer Bilim ve Teknolojisi | tr_TR |
dc.contributor.department | Polymer Science and Technology | en_US |
dc.date | 2008 | tr_TR |
dc.date.accessioned | 2008-07-11 | tr_TR |
dc.date.accessioned | 2015-06-16T12:14:45Z | |
dc.date.available | 2015-06-16T12:14:45Z | |
dc.date.issued | 2008-07-11 | tr_TR |
dc.description | Tez (Yüksek Lisans) -- İstanbul Teknik Üniversitesi, Fen Bilimleri Enstitüsü, 2008 | tr_TR |
dc.description | Thesis (M.Sc.) -- İstanbul Technical University, Institute of Science and Technology, 2008 | en_US |
dc.description.abstract | Bu çalışmada, polietilendiyoksitiyofen homopolimeri ile polietilendiyoksitiyofen ¶tolisülfonilpirol kopolimerinin karbon-fiber mikro buton elektrod üzerindeki elektrokimyasal polimerizasyonları gerçekleştirilmiştir.Elektropolimerizasyon ve dopamin tayini için döngülü voltametri, diferansiyel puls voltametri ve kronoamperometri gibi yöntemler kullanılmıştır.Ayrıca, polietilendiyoksitiyofen kaplanmış elektrodun farklı dopamin derişimine sahip çözeltilerde elektrokimyasal empedans spektroskopi karakterizasyonu yapılmış,eşdeğer devre modeli çizilmiştir.Buradaki sonuçlar,çözeltideki dopamine konsantrasyonunun empdedans değerlerini etkilediği yönünde olmuştur. | tr_TR |
dc.description.abstract | In this thesis, the electrochemical coatings of PEDOT and P(Edot-co-pTsp) copolymer onto carbonfiber micro button electrode were examined. Different electropolymerization and dopamine detection methods;DPV,CV,Chronoamperometry were analyzed and compared for the best current response against dopamine.EIS characterization of PEDOT/CFMBE immersed solutions of different dopamine concentrations was also studied which is a quite new research area. The electrochemical parameters of the CFBME/PEDOT/Electroyte system were evaluated by employing The ZSimpWin (version 3.10) software from Princeton Applied Research.The results showed us,the EIS parameters depend on the dopamine concentration of a solution,thus EIS can be also used as dopamine detection in a system. | en_US |
dc.description.degree | Yüksek Lisans | en_US |
dc.description.degree | M.Sc. | tr_TR |
dc.identifier.uri | http://hdl.handle.net/11527/5652 | |
dc.publisher | Fen Bilimleri Enstitüsü | tr_TR |
dc.publisher | Institute of Science and Technology | en_US |
dc.rights | İTÜ tezleri telif hakkı ile korunmaktadır. Bunlar, bu kaynak üzerinden herhangi bir amaçla görüntülenebilir, ancak yazılı izin alınmadan herhangi bir biçimde yeniden oluşturulması veya dağıtılması yasaklanmıştır. | tr_TR |
dc.rights | İTÜ theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. | en_US |
dc.subject | PEDOT | tr_TR |
dc.subject | P(Edot-ko-pTsp) | tr_TR |
dc.subject | Biyosensor | tr_TR |
dc.subject | Dopamin | tr_TR |
dc.subject | elektrokimyasal empedans spektroskopisi | tr_TR |
dc.subject | difarensiyel puls voltametri | tr_TR |
dc.subject | döngülü voltametri | tr_TR |
dc.subject | PEDOT | en_US |
dc.subject | P(Edot-co-pTsp) | en_US |
dc.subject | Biosensor | en_US |
dc.subject | Dopamine | en_US |
dc.subject | EIS | en_US |
dc.subject | DPV | en_US |
dc.subject | CV | en_US |
dc.title | Polietilendioksitiyofen-paratolisülfonilpirol Kopolimerinin Karbonfiber Mikro Buton Elektrod Üzerinde Empedans Ve Biyosensor Davranışı | tr_TR |
dc.title.alternative | Impedance And Biosensor Behaviour Of Poly(ethylenedioxithiophene-co- P-tolylsulfonylpyrrole) On Carbon Fiber Micro Button Electrode | en_US |
dc.type | Master Thesis | en_US |