Betonarme Yapılarda İzolatör Kullanımının Taşıyıcı Sistem Davranışına Etkileri
| dc.contributor.advisor | Öztürk, Turgut | |
| dc.contributor.author | Gökhan, Eylem | |
| dc.contributor.department | Yapı Mühendisliği | |
| dc.contributor.department | Structural Engineering | |
| dc.date | 2009 | |
| dc.date.accessioned | 2009-02-04 | |
| dc.date.accessioned | 2015-07-03T11:26:51Z | |
| dc.date.available | 2015-07-03T11:26:51Z | |
| dc.date.issued | 2009-02-16 | |
| dc.description | Tez (Yüksek Lisans) -- İstanbul Teknik Üniversitesi, Fen Bilimleri Enstitüsü, 2009 | |
| dc.description | Thesis (M.Sc.) -- İstanbul Technical University, Institute of Science and Technology, 2009 | |
| dc.description.abstract | Bu çalışmada, yapının periyodunu uzatarak yapıya gelen deprem etkilerini azaltmak amacıyla, taban yalıtımı sistemiyle kauçuk izolatör kullanımının, taşıyıcı sistem davranışına olan etkileri araştırılmıştır. Öncelikle yapısal kontrol sistemi yaklaşımının genel değerlendirilmesi yapılmış ardından pasif kontrol sistemlerinin sınıflandırılması yapılarak uygulama örneklerine yer verilmiştir. Son olarak, zaman tanım alanında lineer olmayan analiz yöntemi kullanılarak sekiz katlı betonarme bir yapının taban ankastre hali ve taban izolasyonlu haline ait dinamik analizler yapılmıştır. Analizler sonucunda elde edilen periyot, göreli kat ötelemeleri, maksimum kat ivmeleri ve kesme kuvvetleri karşılaştırmalı olarak sunulmuştur. Seçilen taban izolasyonu sisteminin, yapının periyodunu arttırarak zemin ve yapı etkileşimini minimize ettiği ve geleneksel yöntemlere göre, taşıyıcı sistem davranışındaki olumlu etkileri sayesinde yapıda hasar oluşma riskini azalttığı sonucuna varılmıştır. | |
| dc.description.abstract | In this study, the effects of base isolation system use, mainly rubber isolator, on bearing system response are investigated with the purpose of decreasing the earthquake effects on structure by prolonging the period of the structure. First of all, general evaluation of structural control system is made, then passive control systems are classified and application samples are mentioned. Lastly, by using nonlinear time history analysis method, dynamic analysis of fixed-base state and base isolated state of concrete structure with eight stories are conducted. As a result; observed periods, storey drifts, maximum story accelerations, and shear forces are compared. It is concluded that selected base isolation system minimized the interaction between ground and structure by prolonging the period of structure and decreased the risk of damage to the structure by the positive effects on bearing system response compared to traditional approaches. | |
| dc.description.degree | Yüksek Lisans | |
| dc.description.degree | M.Sc. | |
| dc.identifier.uri | http://hdl.handle.net/11527/6439 | |
| dc.publisher | Fen Bilimleri Enstitüsü | |
| dc.publisher | Institute of Science and Technology | |
| dc.rights | İTÜ tezleri telif hakkı ile korunmaktadır. Bunlar, bu kaynak üzerinden herhangi bir amaçla görüntülenebilir, ancak yazılı izin alınmadan herhangi bir biçimde yeniden oluşturulması veya dağıtılması yasaklanmıştır. | |
| dc.rights | İTÜ theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. | |
| dc.subject | Pasif kontrol sistemleri | |
| dc.subject | Taban yalıtımı | |
| dc.subject | Kauçuk izolatör | |
| dc.subject | Passive control systems | |
| dc.subject | base isolation | |
| dc.subject | rubber isolator | |
| dc.title | Betonarme Yapılarda İzolatör Kullanımının Taşıyıcı Sistem Davranışına Etkileri | |
| dc.title.alternative | Effects Of Isolator Used On Bearing System Response In Concrete Structures | |
| dc.type | Master Thesis |