Co2 Kullanılan Kaskad Soğutma Sisteminin Analizi

dc.contributor.advisor Özgüç, A. Feridun tr_TR
dc.contributor.author Çerkezoğlu, Berkan tr_TR
dc.contributor.department Isı Akışkan tr_TR
dc.contributor.department Head and Fluids en_US
dc.date 2010 tr_TR
dc.date.accessioned 2010-02-17 tr_TR
dc.date.accessioned 2015-05-15T07:32:23Z
dc.date.available 2015-05-15T07:32:23Z
dc.date.issued 2010-02-24 tr_TR
dc.description Tez (Yüksek Lisans) -- İstanbul Teknik Üniversitesi, Fen Bilimleri Enstitüsü, 2010 tr_TR
dc.description Thesis (M.Sc.) -- İstanbul Technical University, Institute of Science and Technology, 2010 en_US
dc.description.abstract Soğutma sistemlerinde temel amaç soğuk bir ortamdan ısı çekmektir. Buhar sıkıştırmalı soğutma sistemlerindeki evaporatörlerde soğutulan ortamdan çekilen ısı yardımıyla devredeki soğutucu akışkan buharlaştırılır, kompresör aracılığı ile sıkıştırılır ve kondenser yardımıyla daha sıcak bir ortama ısı atılır. Kaskad soğutma sistemlerinde ise birden fazla kademe vardır. İki kademeli kaskad soğutma sisteminde düşük sıcaklık kademesinin kondenseri yüksek sıcaklık kademesinin evaporatörü olarak çalışmaktadır. Kaskad ısı değiştirici, düşük sıcaklık kademesinde dolaşan soğutucu akışkandan çektiği ısı yardımıyla yüksek sıcaklık kademesindeki soğutucu akışkanı buharlaştırırken, düşük sıcaklıktaki soğutucu akışkan ise yoğuşur. Bu tez çalışmasında düşük sıcaklık kademesinde karbondioksit kullanılan kaskad soğutma sistemleri tanıtılmış, kaskad soğutma devresi kurulumunda korozyon, karbondioksit sızıntısı, soğutma sisteminin durdurulması, devredeki karbondioksitin aşırı soğutma ve aşırı kızdırma işlemleri, soğutma sisteminde yağlama, buz çözme, kötü kokuların giderilmesi gibi göz önünde bulundurulması gereken önemli noktalara değinilmiştir. Karbondioksit sıcaklık, basınç, soğutma tesir katsayısı, kapasite gibi yönlerden diğer soğutucu akışkanlarla karşılaştırılmıştır. Önemli devre elemanları özellikler doğrudan genişlemeli ve taşırmalı evaporatörler anlatılmış, evaporatör tasarım parametreleri ve optimal devre kurulum şekillerine dikkat çekilmiştir. Soğutma sistemi kurulumundaki bazı kritik tasarım parametrelerine değinilmiştir. Termodinamik incelemede R404A CO2 kaskad soğutma sistemlerinde çeşitli yoğuşma ve buharlaşma sıcaklıkları için soğutma tesir katsayısı, verim, ısı değiştirici kapasiteleri, gerekli net kompresör güçleri ve devrelerde dolaşan akışkan debileri hesaplanmış ve çıkan sonuçlar irdelenmiştir. tr_TR
dc.description.abstract The basic goal of refrigeration systems are to remove heat from a cold medium. In evaporators of vapour compression refrigeration systems refrigerant in the circuit is being evaporated with the help of the heat which is removed from the cold medium, then the refrigerant is being compressed and the heat is being transferred to the warm medium via condensers. There are multiple stages in cascade refrigeration systems. In a two-stage cascade refrigeration system the cascade heat exchanger is the evaporator of high temperature stage and the condenser of the low temperature stage. Cascade heat exchanger evaporates the high temperature refrigerant with the help of the heat which is rejected from the low temperature refrigerant as the low temperature refrigerant is being condensed. In this thesis cascade refrigeration systems which are using carbon dioxide as a refrigerant in low temperature level are introduced. Practical aspects in carbon dioxide refrigeration circuit installations such as corrosion, carbon dioxide leakage, system shut-down, superheating and subcooling operations, lubrication, defrost, and removing fouling are discussed. Carbon dioxide is compared with other refrigerants by means of temperature, pressure, COP of refrigeration, capacity and etc. Important system components especially direct expansion and flooded flow evaporators are covered. Some critical design parameters and optimal system installation methods are described. In thermodynamic analysis COP of refrigeration, efficiency, heat exchanger and compressor capacities, and mass flow rates are being calculated. Also there is a discussion about these results. en_US
dc.description.degree Yüksek Lisans tr_TR
dc.description.degree M.Sc. en_US
dc.identifier.uri http://hdl.handle.net/11527/1867
dc.publisher Fen Bilimleri Enstitüsü tr_TR
dc.publisher Institute of Science and Technology en_US
dc.rights İTÜ tezleri telif hakkı ile korunmaktadır. Bunlar, bu kaynak üzerinden herhangi bir amaçla görüntülenebilir, ancak yazılı izin alınmadan herhangi bir biçimde yeniden oluşturulması veya dağıtılması yasaklanmıştır. tr_TR
dc.rights İTÜ theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. en_US
dc.subject Karbondioksit tr_TR
dc.subject R404A tr_TR
dc.subject Kaskad tr_TR
dc.subject Soğutma tr_TR
dc.subject Sistemi tr_TR
dc.subject Carbon en_US
dc.subject Dioxide en_US
dc.subject R404A en_US
dc.subject Cascade en_US
dc.subject Refrigeration en_US
dc.subject System en_US
dc.title Co2 Kullanılan Kaskad Soğutma Sisteminin Analizi tr_TR
dc.title.alternative Analysis Of A Cascade Refrigeration System Using Co2 As A Refrigerant en_US
dc.type Master Thesis en_US
Dosyalar
Orijinal seri
Şimdi gösteriliyor 1 - 1 / 1
thumbnail.default.alt
Ad:
10163.pdf
Boyut:
1.57 MB
Format:
Adobe Portable Document Format
Açıklama