Çok Katlı Tüp Sistem Çerçeveli Betonarme Bir Binanın Tasarımı

dc.contributor.advisor Aydoğan, Metin tr_TR
dc.contributor.author Aydın, Mahir Onur tr_TR
dc.contributor.department Yapı Mühendisliği tr_TR
dc.contributor.department Structural Engineering en_US
dc.date 2004 tr_TR
dc.date.accessioned 2015-12-01T13:54:54Z
dc.date.available 2015-12-01T13:54:54Z
dc.description Tez (Yüksek Lisans) -- İstanbul Teknik Üniversitesi, Fen Bilimleri Enstitüsü, 2004 tr_TR
dc.description Thesis (M.Sc.) -- İstanbul Technical University, Institute of Science and Technology, 2004 en_US
dc.description.abstract Yüksek lisans tezi olarak, yapılan bu çalışmada 20 katlı bir betonarme ofis binasının deprem yükleri ve artırılmış düşey yükler etkisindeki davranışı ve tasarım aşamaları irdelenmiştir. Proje olarak, taşıyıcı sistemi tüp çerçevelerden ve perdelerden oluşan bir işyeri binası ele alınmıştır. Yapıda kullanılan malzeme özellikleri, yükleme durumları, yapı elemanlarının ön boyutları binaya ve taşıyıcı sisteme ait geometrik ve fiziksel özellikler, davranış biçimleri, binanın konumu, zemin özellikleri gibi çeşitli kabuller uygun görüldükleri ve sistemi zorlamaya yönelik şekillerde yapılmıştır. Uygulanan yükler altında kesit etkilerinin saptanmasında, bilgisayar ortamında üç boyutlu olarak ve sonlu elemanlarla çözüm yapan SAP2000 yapısal analiz programı kullanılmıştır. Söz konusu yapı 1. deprem bölgesinde olup, 4 bodrum kattan 1 zemin kattan ve 15 normal kattan oluşmakta ve iş merkezi olarak kullanılması amaçlanmaktadır. Zemin ve normal katların yüksekliği 3 m, bodrum katların yüksekliği 4 m dir. Döşemeler kirişli döşeme tipinde olup, taşıyıcı sistem tüp çerçeve ve perdelerden oluşmaktadır. Malzeme olarak BS25 ve BÇIIIa (S420) kullanılmıştır. Yapıda taşıyıcı sistem oluşturulurken önce TS 498 de verilen sabit ve hareketli düşey yükler altında döşemelerin ve kirişlerin kesit tesirlerini hesaplamak üzere tek katlı, sonlu ve çubuk elemanlardan oluşan model düzenlenmiştir. Modelin boyutlandırılmasında TS500 ve Deprem Yönetmeliğine uygunluklar, sehim kontrolü yapılmıştır. Binanın deprem kuvvetleri etkisindeki davranışını incelemek amacıyla ABYYHY’de anlatılan Eşdeğer Deprem Yükü yöntemine göre belirlenen kuvvetler bilgisayar modelinde etki ettirilmiştir. Ayrıca SAP2000 programıyla Spektral Analiz metodu yapıya uygulanarak sonuçlar karşılaştırılmıştır. tr_TR
dc.description.abstract The design procedure of a 20 storey reinforced concrete building and its behaviour under seismic loads and increased vertical loads, is considered as master thesis. The Project in this context, a business center, consisting of concrete exterior tube and shear walls support system, has been chosen to study. Three dimensional modelling of the building is made using SAP2000 programme, to determine the section effects under the loads. The building under consideration is located in 1st degree seismic zone which consist of 4 basement stories, ground floor and 15 official stories. It is designed to be business center. The basement stories are 4m, the ground floor and official stories are 3m in height. The floor slabs are plates and structural system consist of exterior tube with closely spaced columns and shear walls. As materials C25 concrete and S420 steel are used. First of all, under the effects under dead and live vertical loads that are presented in TS 498, preliminary dimensions are assigned to the structural elements according to the criteria mentioned in TS 500. In the realization of the model, TS 500 and Turkish Earthquake Code compatibility was verified. For the purpose of considering the behaviour of the building under lateral seismic effects, the loads found according to the Equivalent Seismic Load Method presented in Turkish Earthquake Code are used in computer model. In addition, Spectral Analysis method using the SAP2000 programme is applied to the building. Using the results obtained from the Equivalent Seismic Loads method, the reinforced concrete sectional calculations of the ground floor columns and beams, shear walls located in center zone and the mat foundation with adequate thickness in which punching effects are sustained without any steel reinforcement. Also, the calculations of the basement surrounding shear walls are made under the effects of the static and dynamic earth pressure. en_US
dc.description.degree Yüksek Lisans tr_TR
dc.description.degree M.Sc. en_US
dc.identifier.uri http://hdl.handle.net/11527/10863
dc.publisher Fen Bilimleri Enstitüsü tr_TR
dc.publisher Institute of Science and Technology en_US
dc.rights İTÜ tezleri telif hakkı ile korunmaktadır. Bunlar, bu kaynak üzerinden herhangi bir amaçla görüntülenebilir, ancak yazılı izin alınmadan herhangi bir biçimde yeniden oluşturulması veya dağıtılması yasaklanmıştır. tr_TR
dc.rights İTÜ theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. en_US
dc.subject Çok Katlı Yapılar tr_TR
dc.subject Tüp Sistem tr_TR
dc.subject Yapı Analizi tr_TR
dc.subject Multi Storey Buildings en_US
dc.subject Tube Systems en_US
dc.subject Structural Analysis en_US
dc.title Çok Katlı Tüp Sistem Çerçeveli Betonarme Bir Binanın Tasarımı tr_TR
dc.title.alternative The Design Of A Framed Multi-storey Reinforced Concrete Building Having Tube System en_US
dc.type Master Thesis en_US
Dosyalar
Orijinal seri
Şimdi gösteriliyor 1 - 1 / 1
thumbnail.default.alt
Ad:
2338.pdf
Boyut:
2.03 MB
Format:
Adobe Portable Document Format
Açıklama
Lisanslı seri
Şimdi gösteriliyor 1 - 1 / 1
thumbnail.default.placeholder
Ad:
license.txt
Boyut:
3.14 KB
Format:
Plain Text
Açıklama