Mevcut Betonarme Bir Okul Binasının Performansının Değerlendirilmesi Ve Sismik İzolasyon Kullanılarak Güçlendirilmesi

dc.contributor.advisor Taşkın, Beyza tr_TR
dc.contributor.author Tokuç, M.orçun tr_TR
dc.contributor.department Deprem Mühendisliği tr_TR
dc.contributor.department Earthquake Engineering en_US
dc.date 2008 tr_TR
dc.date.accessioned 2008-02-05 tr_TR
dc.date.accessioned 2015-09-02T07:50:10Z
dc.date.available 2015-09-02T07:50:10Z
dc.description Tez (Yüksek Lisans) -- İstanbul Teknik Üniversitesi, Fen Bilimleri Enstitüsü, 2008 tr_TR
dc.description Thesis (M.Sc.) -- İstanbul Technical University, Institute of Science and Technology, 2008 en_US
dc.description.abstract Bu çalışmada, mevcut betonarme bir okul binasının performansı değerlendirilip, sismik izolasyon kullanılarak yapı tekrardan değerlendirilmiştir. Doğrusal olmayan statik analiz yöntemi kullanılarak yapının statik itme eğrisi oluşturulmuştur. Hemen kullanım ve can güvenliği performans düzeyleri için performans noktaları belirlenmiştir. Bu performans noktalarında kesitlerde oluşan plastik mafsal istemleri belirlenmiştir. Kesitlere ait toplam eğrilikler belirlenerek, bu eğrilikler beton ve çelik malzemesinin sınırları ile kıyaslanmış ve yapının performans seviyesi belirlenmiştir. Mevcut bu binanın her iki performans seviyesini sağlayamadığı tespit edilmiştir. Bu yüzden sistemin sismik izolasyon ile güçlendirilmesine karar verilmiştir. Bu yapı için kurşun çekirdekli kauçuk esaslı izolatör tasarlanmıştır. Sismik izolasyon uygulanan binanın belirli deprem verileri altında doğrusal olmayan zaman tanım alanında dinamik çözümleri yapılmıştır. Yapını sismik izolasyonlu hali için elde edilen değerler ankastre mesnetli yapı için karşılaştırılmıştır. Bunun sonucunda yapının sismik izolasyonlu hali için daha az deprem tesirleri aldığı saptanmıştır. tr_TR
dc.description.abstract In this study, seismic performance of an existing reinforced-concrete school building has been evaluated and by introducing seismic isolation, structural system has been investigated again. Applying non-linear static analysis procedure, the pushover curve is obtained.Assuming immediate occupancy and life safety performance levels, the perfromance levels are determined. The curvatures for the related sections are computed and are compared with the code limits. Moreover seismic performance level of the entire is determined. The existing building is found to be failing to satisfy both perfromance levels therefore it is decided to be retrofitted by base isolation. The lead rubber bearing isolation devices are designed for the structure and nonlinear time history analysis method is implemented for the seismically isolated building under the selected earthquake data. The results for the isolated building have been compared for the fixed-based existing case. Consequently, it has been determined that the base isolated structure has been subjected to less earthquake effects. en_US
dc.description.degree Yüksek Lisans tr_TR
dc.description.degree M.Sc. en_US
dc.identifier.uri http://hdl.handle.net/11527/8829
dc.publisher Fen Bilimleri Enstitüsü tr_TR
dc.publisher Institute of Science and Technology en_US
dc.rights İTÜ tezleri telif hakkı ile korunmaktadır. Bunlar, bu kaynak üzerinden herhangi bir amaçla görüntülenebilir, ancak yazılı izin alınmadan herhangi bir biçimde yeniden oluşturulması veya dağıtılması yasaklanmıştır. tr_TR
dc.rights İTÜ theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. en_US
dc.subject Betonarme tr_TR
dc.subject Performans tr_TR
dc.subject Plastik Mafsal tr_TR
dc.subject Sismik İzolasyon tr_TR
dc.subject Reinforced-concrete en_US
dc.subject Performance en_US
dc.subject Plastic Hinge en_US
dc.subject Seismic Isolation en_US
dc.title Mevcut Betonarme Bir Okul Binasının Performansının Değerlendirilmesi Ve Sismik İzolasyon Kullanılarak Güçlendirilmesi tr_TR
dc.title.alternative Assessment Of The Performance Of An Existing Reinforced Concrete School Building And Retrofitting By Using The Seismic Isolation en_US
dc.type masterThesis en_US
Dosyalar
Orijinal seri
Şimdi gösteriliyor 1 - 1 / 1
thumbnail.default.alt
Ad:
7834.pdf
Boyut:
95.06 MB
Format:
Adobe Portable Document Format
Açıklama
Lisanslı seri
Şimdi gösteriliyor 1 - 1 / 1
thumbnail.default.placeholder
Ad:
license.txt
Boyut:
3.14 KB
Format:
Plain Text
Açıklama