1070 – Nm Yfl Laseri İle Beyin Ve Karaciğer Dokularında Karşılaştırmalı Sıcaklık Ölçümleri
1070 – Nm Yfl Laseri İle Beyin Ve Karaciğer Dokularında Karşılaştırmalı Sıcaklık Ölçümleri
dc.contributor.advisor | Çilesiz, İnci | tr_TR |
dc.contributor.author | Gürkan Özer, Ayşen | tr_TR |
dc.contributor.department | Biyomedikal Mühendisliği | tr_TR |
dc.contributor.department | Biomedical Engineering | en_US |
dc.date | 2008 | tr_TR |
dc.date.accessioned | 2008-07-28 | tr_TR |
dc.date.accessioned | 2015-04-21T12:00:33Z | |
dc.date.available | 2015-04-21T12:00:33Z | |
dc.date.issued | 2008-07-31 | tr_TR |
dc.description | Tez (Yüksek Lisans) -- İstanbul Teknik Üniversitesi, Fen Bilimleri Enstitüsü, 2008 | tr_TR |
dc.description | Thesis (M.Sc.) -- İstanbul Technical University, Institute of Science and Technology, 2008 | en_US |
dc.description.abstract | Laser - doku etkileşimi çalışmalarında, uygulama bölgesi civarında laserin etkisiyle oluşan ısının dağılımı önemlidir. Isınan bölgede oluşan sıcaklıkların ölçülmesi ve kontrol altında tutulması gereklidir. 1070 nm dalgaboyunun sürekli dalga etkisiyle oluşan sıcaklık dağılımı karaciğer ve beyin dokularında incelenmiştir. İncelemeler, beyin ve karaciğer dokularının içerisinde, laser uygulama merkezine 2 mm, 4 mm ve 6 mm uzaklıklardan, 3’ü radyal çaplar üzerinden yatay eksende, diğer 3’ü uygulama merkezinin izdüşümünden düşey eksende olmak üzere, 6 farklı konumdan sıcaklık ölçülerek yapılmıştır. Sıcaklık ölçümlerinde K-tipi ısılçiftler (thermocouple) kullanılmıştır. Sıcaklık, kaynaktan uzaklaştıkça eksenel yönde, radyal yönde olduğundan daha hızlı azalmaktadır. Nedeni, uygulama sırasında koagülasyon bölgesinde artan saçılmalar olup, eksenel yöndeki hızlı azalma aynı zamanda laser ışın demet çapı ile uygulanan dalgaboyu girginliğinin oranı ile de ilintilidir. İncelenen sonuçlar biyoısı denklemiyle uyumlu bulunmuştur. | tr_TR |
dc.description.abstract | Distribution of heat generated by laser-tissue interactions about the irradiation area is essential for the outcome of therapeutic laser applications. Temperatures must be measured, monitored and effectively controlled for optimal results. The temperature distribution created by the 1070 nm continuous wave (cw) laser irradiation was investigated on liver and brain tissues. Observations were made 2 mm, 4 mm, 6 mm away from the laser application center on brain and liver tissues, at 6 different locations, 3 on the radial and the other 3 on the longitudinal axis, respectively. Temperatures were measured and monitored with K-type thermocouples. We observed that temperatures decreased faster axially than radially along the depth in tissue. We speculated that this was caused by the increased scattering in the coagulated area. Faster axial decrease was also affected by the ratio of laser beam size to the penetration depth. Results were consistent with implications of the bioheat equation. | en_US |
dc.description.degree | Yüksek Lisans | tr_TR |
dc.description.degree | M.Sc. | en_US |
dc.identifier.uri | http://hdl.handle.net/11527/808 | |
dc.publisher | Fen Bilimleri Enstitüsü | tr_TR |
dc.publisher | Institute of Science and Technology | en_US |
dc.rights | İTÜ tezleri telif hakkı ile korunmaktadır. Bunlar, bu kaynak üzerinden herhangi bir amaçla görüntülenebilir, ancak yazılı izin alınmadan herhangi bir biçimde yeniden oluşturulması veya dağıtılması yasaklanmıştır. | tr_TR |
dc.rights | İTÜ theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. | en_US |
dc.subject | 1070-nm | tr_TR |
dc.subject | beyin | tr_TR |
dc.subject | karaciğer | tr_TR |
dc.subject | sıcaklık dağılımı | tr_TR |
dc.subject | saçılma | tr_TR |
dc.subject | biyoısı denklemi. | tr_TR |
dc.subject | 1070-nm | en_US |
dc.subject | brain | en_US |
dc.subject | liver | en_US |
dc.subject | heat distribution | en_US |
dc.subject | scattering | en_US |
dc.subject | biyoheat equation. | en_US |
dc.title | 1070 – Nm Yfl Laseri İle Beyin Ve Karaciğer Dokularında Karşılaştırmalı Sıcaklık Ölçümleri | tr_TR |
dc.title.alternative | Comparative Temperature Measurements On Brain And Liver Tissues Using The 1070 Nm Laser | en_US |
dc.type | Master Thesis |