Yayın:
Time-Dependent Changes in Failure Loads of 3 Biceps Tenodesis Techniques

dc.contributor.authorKilicoglu, Onder
dc.contributor.authorKoyuncu, Ozgur
dc.contributor.authorDemirhan, Mehmet
dc.contributor.authorEsenyel, Cem Zeki
dc.contributor.authorAtalar, Ata Can
dc.contributor.authorOzsoy, Serhat
dc.contributor.authorBozdag, Ergun
dc.contributor.authorSunbuloglu, Emin
dc.contributor.authorBilgic, Bilge
dc.contributor.ituauthorBozdağ, Süreyya Ergün
dc.contributor.ituauthorSünbüloğlu, Emin
dc.date.accessioned2026-01-26T05:17:41Z
dc.date.issued2005-10-01
dc.description.abstractBackground Failure load of the tendon–fixation material–bone unit has a crucial importance for the rehabilitation protocol after tenodesis procedures. Purpose To investigate and compare the time-dependent changes in fixation strengths of 3 proximal biceps tenodesis techniques. Study Design Controlled laboratory study. Methods Two intraosseous techniques (suture sling and tenodesis screw) and 1 extraosseous technique (2 suture anchors) were investigated. Biceps tenodesis was performed on 45 shoulders of 26 sheep, 15 shoulders for each technique. Twelve similar cadaveric sheep shoulders (4 for each technique) provided the day 0 results. Sheep were sacrificed at 3, 6, and 9 weeks, and specimens were tested for the failure load of the tenodeses. Results All 3 tenodesis techniques were found to have similar failure loads at all time intervals tested. All 3 curves remained below the failure load of the intact tendon (862 ± 96 N) and above their day 0 results for the study period; similarly, at each time interval, results tended to be better compared to the previous test. The tenodesis screw group exhibited significantly higher failure loads at week 3 (419 ± 53 N) compared to day 0 values (164 ± 45 N) (P=. 009). The same level of significance was observed at week 6 in the remaining 2 groups. Conclusion Tenodesis of the biceps tendon on the proximal humerus at an extra-articular site does not weaken after surgery. The tenodesis screw group had a significantly higher increase in the fixation strength within the first 3 weeks. Clinical Relevance No significant differences could be found between the failure loads of all 3 investigated tenodeses for the first 9 weeks.
dc.description.urihttps://doi.org/10.1177/0363546505274716
dc.description.urihttps://pubmed.ncbi.nlm.nih.gov/16009989
dc.description.urihttps://dx.doi.org/10.1177/0363546505274716
dc.identifier.doi10.1177/0363546505274716
dc.identifier.eissn1552-3365
dc.identifier.endpage1544
dc.identifier.issn0363-5465
dc.identifier.openairedoi_dedup___::eaaddcb37b69574255c5553a5295f97c
dc.identifier.orcid0000-0003-4835-7079
dc.identifier.orcid0000-0001-7412-1129
dc.identifier.orcid0000-0001-9930-4618
dc.identifier.startpage1536
dc.identifier.urihttps://hdl.handle.net/11527/62153
dc.identifier.volume33
dc.language.isoeng
dc.publisherSAGE Publications
dc.relation.ispartofThe American Journal of Sports Medicine
dc.rightsCLOSED
dc.subjectEquipment Failure Analysis
dc.subjectTendons
dc.subjectSheep
dc.subjectTime Factors
dc.subjectAbsorbable Implants
dc.subjectBone Screws
dc.subjectSuture Techniques
dc.subjectAnimals
dc.subjectOrthopedic Procedures
dc.subjectHumerus
dc.titleTime-Dependent Changes in Failure Loads of 3 Biceps Tenodesis Techniques
dc.typeArticle
dspace.entity.typePublication
person.identifier.orcid0000-0001-7412-1129
person.identifier.orcid0000-0001-9930-4618

Dosyalar

Koleksiyonlar