Yayın:
Time-Dependent Changes in Failure Loads of 3 Biceps Tenodesis Techniques

Yükleniyor...
Küçük Resim

Kurum Yazarları

Item type:Araştırmacı/Yazar,
Bozdağ, Süreyya Ergün
Öğretim Görevlisi Dr.
Item type:Araştırmacı/Yazar,
Sünbüloğlu, Emin
Profesor

Danışman

Bölüm / Program

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

SAGE Publications

Türü

Araştırma Projeleri

Akademik Birimler

Dergi Sayısı

Özet

Background Failure load of the tendon–fixation material–bone unit has a crucial importance for the rehabilitation protocol after tenodesis procedures. Purpose To investigate and compare the time-dependent changes in fixation strengths of 3 proximal biceps tenodesis techniques. Study Design Controlled laboratory study. Methods Two intraosseous techniques (suture sling and tenodesis screw) and 1 extraosseous technique (2 suture anchors) were investigated. Biceps tenodesis was performed on 45 shoulders of 26 sheep, 15 shoulders for each technique. Twelve similar cadaveric sheep shoulders (4 for each technique) provided the day 0 results. Sheep were sacrificed at 3, 6, and 9 weeks, and specimens were tested for the failure load of the tenodeses. Results All 3 tenodesis techniques were found to have similar failure loads at all time intervals tested. All 3 curves remained below the failure load of the intact tendon (862 ± 96 N) and above their day 0 results for the study period; similarly, at each time interval, results tended to be better compared to the previous test. The tenodesis screw group exhibited significantly higher failure loads at week 3 (419 ± 53 N) compared to day 0 values (164 ± 45 N) (P=. 009). The same level of significance was observed at week 6 in the remaining 2 groups. Conclusion Tenodesis of the biceps tendon on the proximal humerus at an extra-articular site does not weaken after surgery. The tenodesis screw group had a significantly higher increase in the fixation strength within the first 3 weeks. Clinical Relevance No significant differences could be found between the failure loads of all 3 investigated tenodeses for the first 9 weeks.

Tanım

Dergi veya Seri

The American Journal of Sports Medicine

ISSN

0363-5465

ISBN

Haklar

CLOSED

Anahtar Kelimeler

Equipment Failure Analysis, Tendons, Sheep, Time Factors, Absorbable Implants, Bone Screws, Suture Techniques, Animals, Orthopedic Procedures, Humerus

Alıntı

Koleksiyonlar

Onay

Gözden geçir

Tamamlayıcı Bilgiler

Referans Gösteren

Related Patent

Related Goal

4
Görüntülenme
0
İndirme
Altmetric
Dimensions
PlumX Metrikleri
BIP! Indicators
Google Scholar
Scholar'da Ara ↗