dc.description.abstractAbstractPurposeThe purpose of this study was to compare the mechanical characteristics of meniscal repair fixation using horizontal sutures and two different diameter sutures under submaximal cyclic and load to failure test conditions.MethodA 2‐cm long anteroposterior vertical longitudinal incision was created in two groups of bovine medial menisci. Lesions were repaired using either #2‐0 (Group 1), or #2 (Group 2) Fiberwire suture. Following repair, the lesion was extended through the posterior and anterior meniscal horns so that no tissue secured the repair site. Specimens underwent submaximal cyclic (5–50 N at 1 Hz for 500 cycles) and load to failure testing (5 mm/min crosshead speed) in a servo hydraulic device. Specimen failure mode was verified by the primary investigator. An alpha level of P < 0.05 was selected to indicate statistical significance.ResultsGroup 2 displayed greater load at failure (132.1 ± 54.4 N) than Group 1 (91.9 ± 26.2 N) (P = 0.02). Group 2 also displayed greater stiffness (47.1 ± 8.3 N/mm) than Group 1 (38.5 ± 10.2 N/mm) (P = 0.03). The failure mode for all specimens was suture pull‐through the meniscal tissue. Larger diameter suture provided superior mechanical meniscal fixation.ConclusionIf Horizontal suture would be used in meniscal repair, the most suitable larger diameter suture should be used.
dc.description.urihttps://doi.org/10.1007/s00167-010-1203-4
dc.description.urihttps://pubmed.ncbi.nlm.nih.gov/20602087
dc.description.urihttps://dx.doi.org/10.1007/s00167-010-1203-4
dc.description.urihttps://avesis.deu.edu.tr/publication/details/eefd06d7-445a-4336-a6e8-a4be81958b7a/oai
dc.identifier.doi10.1007/s00167-010-1203-4
dc.identifier.eissn1433-7347
dc.identifier.endpage206
dc.identifier.issn0942-2056
dc.identifier.openairedoi_dedup___::f36cb839b2ff3959a817c6d621dac737
dc.identifier.orcid0000-0001-9930-4618
dc.identifier.orcid0000-0001-7412-1129
dc.identifier.startpage202
dc.identifier.urihttps://hdl.handle.net/11527/63323
dc.identifier.volume19
dc.language.isoeng
dc.publisherWiley
dc.relation.ispartofKnee Surgery, Sports Traumatology, Arthroscopy
dc.rightsCLOSED
dc.subjectEquipment Failure Analysis
dc.subjectSutures
dc.subjectMaterials Testing
dc.subjectAnimals
dc.subjectCattle
dc.subjectEquipment Design
dc.subjectMenisci, Tibial
dc.subjectTibial Meniscus Injuries
dc.titleMeniscal repair using large diameter horizontal sutures increases fixation strength: an in vitro study
dc.typeArticle
dspace.entity.typePublication
person.identifier.orcid0000-0001-9930-4618
person.identifier.orcid0000-0001-7412-1129

Dosyalar

Koleksiyonlar