Polipropilen Lif Kullanım Oranının Beton Karışımlarının Dayanımına Etkisi
Polipropilen Lif Kullanım Oranının Beton Karışımlarının Dayanımına Etkisi
dc.contributor.author | Mardani-Aghabaglou, Ali | tr_TR |
dc.contributor.author | Altun, Muhammet Gökhan | tr_TR |
dc.contributor.author | Yılmaz, Gökhan | tr_TR |
dc.date | 2017 | tr_TR |
dc.date.accessioned | 2020-06-22T17:01:07Z | |
dc.date.available | 2020-06-22T17:01:07Z | |
dc.date.issued | 2017 | |
dc.description | Konferans Bildirisi-- İstanbul Teknik Üniversitesi, Teorik ve Uygulamalı Mekanik Türk Milli Komitesi, 2017 | tr_TR |
dc.description | Conference Paper -- İstanbul Technical University, Theoretical and Applied Mechanical Turkish National Committee, 2017 | en_US |
dc.description.abstract | Bu çalışmada, polipropilen lif kullanım oranının beton karışımlarının dayanım özellikleri ve ultrases geçiş hızına etkisi incelenmiştir. Bu amaçla, lif içermeyen kontrol karışımına ilaveten hacimce %0,4, %0,8 ve %1 oranlarında polipropilen lif kullanılarak 3 farklı beton karışımı hazırlanmıştır. Beton karışımlarının üretimi için bağlayıcı olarak CEMI 42,5 R tipi portland çimentosu ve maksimum tane çapı 25 mm olan kırma kireçtaşı agregası kullanılmıştır. Tüm beton karışımlarında su/çimento oranı, çimento dozajı ve çökme miktarı sırasıyla, 0,45, 350 kg/m3 ve 130±10 mm olarak sabit tutulmuştur. İstenen çökme miktarını sağlamak amacı ile polikarboksilat-eter esaslı yüksek oranda su azaltıcı katkı kullanılmıştır. Beton karışımlarının 1, 3, 7 ve 28 günlük basınç dayanımı, 7 ve 28 günlük yarmada çekme dayanımı ve 28 günlük ultrases geçiş hızı değerleri 150 mm küp numuneler üzerinde belirlenmiştir. Ayrıca, beton karışımlarının 7 ve 28 günlük orta nokta yüklemeli eğilme dayanımı 100x100x600 mm'lik prizma numunelerinde elde edilmiştir. Test sonuçları, hacimce %0,8 polipropilen lif içeren beton karışımının en yüksek mukavemet ve ultrases geçiş hızına sahip olduğunu göstermiştir. Bahsedilen lif kullanım oranının ötesinde, beton karışımının dayanımı olumsuz etkilenmiştir. | tr_TR |
dc.description.abstract | In this study, the effect of polypropylene fibre utilization level on the strength properties and ultrasonic pulse velocity of concrete mixtures were investigated. For this purpose, in addition to the control mixture containing no fibre, three different concrete mixtures were prepared by utilization of polypropylene fibre as 0.4%, 0.8% and 1% by volume. A CEMI 42.5 R type portland cement as binder and crushed limestone aggregate having a maximum particle size of 25 mm were used for production of concrete mixtures. In all concrete mixtures, water/cement ratio, cement content and slump values were kept constant as 0,45, 350 kg/m3 and 130±10 mm, respectively. A polycarboxylate ether-based high range water reducing admixture was used for providing desired slump value. 1, 3, 7 and 28-day compressive strength, 7 and 28-day splitting tensile strength and 28-day ultrasonic pulse velocity values of concrete mixtures were measured on 150 mm cube specimens. Besides, center-point loading flexural strength of 100x100x600 mm prism specimens were obtained at 7 and 28-day ages. Test results demonstrated that concrete mixture containing polypropylene fibre as 0.8% by volume had the highest strength and ultrasonic pulse velocity. Beyond mentioned utilization ratio of fibre, strength properties of concrete mixture were negatively affected. | en_US |
dc.identifier.uri | http://hdl.handle.net/11527/18317 | |
dc.language | tr | tr_TR |
dc.publisher | Teorik ve Uygulamalı Mekanik Türk Milli Komitesi | tr_TR |
dc.publisher | Theoretical And Applied Mechanical Turkish National Committee | en_US |
dc.relation.ispartofseries | 20. Ulusal Mekanik Kongresi | tr_TR |
dc.rights | Kurumsal arşive yüklenen tüm eserler telif hakkı ile korunmaktadır. Bunlar, bu kaynak üzerinden herhangi bir amaçla görüntülenebilir, ancak yazılı izin alınmadan herhangi bir biçimde yeniden oluşturulması veya dağıtılması yasaklanmıştır. | tr_TR |
dc.rights | All works uploaded to the institutional repository are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. | en_US |
dc.title | Polipropilen Lif Kullanım Oranının Beton Karışımlarının Dayanımına Etkisi | tr_TR |
dc.type | Conference Paper | en_US |
dc.type | Konferans Bildirisi | tr_TR |