Tarihi Tuğlalar İle Örülen Duvarların Güçlendirilmesi

dc.contributor.advisor İlki, Alper tr_TR
dc.contributor.author Aş, Emriye Fundagül tr_TR
dc.contributor.department Deprem Mühendisliği tr_TR
dc.contributor.department Earthquake Engineering en_US
dc.date 2007 tr_TR
dc.date.accessioned 2015-09-02T07:50:08Z
dc.date.available 2015-09-02T07:50:08Z
dc.description Tez (Yüksek Lisans) -- İstanbul Teknik Üniversitesi, Fen Bilimleri Enstitüsü, 2007 tr_TR
dc.description Thesis (M.Sc.) -- İstanbul Technical University, Institute of Science and Technology, 2007 en_US
dc.description.abstract Bu çalışmada Osmanlı Mimarisinde sıraev konut tipinin ilk örneği olan Akaretler Sıraev Grubu taşıyıcı duvarlarından alınan tuğlalar ile örülen duvar numunelerinin güçlendirme öncesi ve sonrasında diyagonal çekme etkisi altında davranışı incelenmiştir. Bu amaçla Akaretler Sıraev Grubunun taşıyıcı duvarlarının mekanik özelliklerini olabildiğince yansıtan 12 adet duvar numunesi üretilmiştir. Yaklaşık boyutları 400x400x260 mm3 olarak üretilen numunelerin; 2 adedi herhangi bir güçlendirme işlemine tabi tutulmadan referans davranışı belirlemek üzere, 2 adedi tamir harcı ile 8 adedi de cam lifli polimer kompozitler ile güçlendirilerek monoton artan veya tekrarlı yükler altında diyagonal çekme deneyi ile denenmiştir. LP kompozitler ile güçlendirilen numunelerde, kompozit kalınlığı, kompozitlerin duvar numunesine ankrajı ve tekrarlı yüklemenin davranışa etkisi incelenmiştir. Deneysel çalışma sonucunda; LP kompozitler güçlendirme uygulaması ile numunelerin dayanımlarında belirgin bir artış gözlenmiş, ankraj uygulamasınında numunelerin göçme biçimindeki iyileşme ile dayanım ve şekildeğiştirme yeteneklerinde ki artışta önemli rol oynadığı görülmüştür. Tekrarlı yükler altında denenen numunelerin davranışı ile monotonik yükler altında denenen numunelerin davranışı arasında belirgin bir fark görülmemiştir. tr_TR
dc.description.abstract In this study, the behaviour of the retrofitted walls, which were constructed using historical bricks of the Akaretler Row Houses, the first example of row houses in the Ottoman period, is investigated. For this purpose, 12 masonry wall specimens, with similar mechnical characteristics of the masonry walls of Akaratler Row Houses, were constructed and then retrofitted. The dimensions of wall specimens were approximately 400x400x260 mm3. Two of the specimens were retrofitted with a plaster made of repair mortar, eight of the specimens were retrofitted with glass fiber polymers over the plaster of repair mortar and two specimens were tested as reference without any retrofit. Masonry wall specimens were tested under monotonic increasing or cyclic loading in diagonal tension test. The effects of existence of plaster, thickness of FRP sheets, types of anchorages of FRP sheets to the masonry walls were investigated. In addition to these; the effects of cycling loading on the behavior were examined by testing a single specimen with the similar characteristics to another specimen tested under monotonic loading. At the end of the tests, it was concluded that the strength of the historical masonry walls can be increased significantly using FRP sheets over a high quality plaster, provided that adequate anchorage of FRP sheets to the masonry walls are mainteined. Being relatively less pronounced even the plaster itself contributed to the strength of the wall specimens. By the retrofitting of the historical walls, the deformability of the walls were also enchanced, particularly for the appropriately anchored FRP sheets. The cyclic loading was not found to be significantly effective on the bahavior of FRP retrofitted historical brick walls. en_US
dc.description.degree Yüksek Lisans tr_TR
dc.description.degree M.Sc. en_US
dc.identifier.uri http://hdl.handle.net/11527/8825
dc.publisher Fen Bilimleri Enstitüsü tr_TR
dc.publisher Institute of Science and Technology en_US
dc.rights İTÜ tezleri telif hakkı ile korunmaktadır. Bunlar, bu kaynak üzerinden herhangi bir amaçla görüntülenebilir, ancak yazılı izin alınmadan herhangi bir biçimde yeniden oluşturulması veya dağıtılması yasaklanmıştır. tr_TR
dc.rights İTÜ theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. en_US
dc.subject tarihi tuğla tr_TR
dc.subject yığma duvar tr_TR
dc.subject güçlendirme tr_TR
dc.subject cam lifli polimer kompozit tr_TR
dc.subject historical brick en_US
dc.subject masonry wall en_US
dc.subject retrofitting en_US
dc.subject glass fiber polimer en_US
dc.title Tarihi Tuğlalar İle Örülen Duvarların Güçlendirilmesi tr_TR
dc.title.alternative Retrofitting Of Masonry Walls Built Using Historical Bricks en_US
dc.type Master Thesis en_US
Dosyalar
Orijinal seri
Şimdi gösteriliyor 1 - 1 / 1
thumbnail.default.alt
Ad:
7563.pdf
Boyut:
5.59 MB
Format:
Adobe Portable Document Format
Açıklama
Lisanslı seri
Şimdi gösteriliyor 1 - 1 / 1
thumbnail.default.placeholder
Ad:
license.txt
Boyut:
3.14 KB
Format:
Plain Text
Açıklama