Çelik Depo Raf Sistemlerinde Kullanılan Yatay Taşıyıcıya Oturan Tava Rafların Kapasitelerinin Analitik Ve Sonlu Elemanlar Yöntem

dc.contributor.author Pala, Yaşar tr_TR
dc.contributor.author Çalış, Emre tr_TR
dc.date 2017 tr_TR
dc.date.accessioned 2020-06-22T17:01:16Z
dc.date.available 2020-06-22T17:01:16Z
dc.date.issued 2017
dc.description Konferans Bildirisi-- İstanbul Teknik Üniversitesi, Teorik ve Uygulamalı Mekanik Türk Milli Komitesi, 2017 tr_TR
dc.description Conference Paper -- İstanbul Technical University, Theoretical and Applied Mechanical Turkish National Committee, 2017 en_US
dc.description.abstract Bu çalışmada, hafif ve kutulu yükler için paletli depo raf sistemlerinde kullanılan yatay taşıyıcıya oturan tava raf sistemlerinin kapasitelerinin belirlenmesi üzerinde durulmuştur. İstenilen yükleme boyutları altında tava rafların taşıma kapasiteleri hem analitik olarak hem de sonlu elemanlar analizi ile belirlenmiştir. Tava rafın 2a x 2a boyutlu bir bölgesi üzerinde yayılı kuvvetlere maruz kaldığı kabul edilmiştir. Kuvvetler arası mesafenin k olduğu ve 2a uzunluğunda n adet kuvvet bulunduğu kabul edilmiştir. Buradan hareketle her bir tekil kuvvetin şiddeti toplam kuvvet cinsinden bulunmuştur. Daha sonra tava raf kesitini oluşturan her bir parçanın taşımış olduğu momentler bulunarak her bir elemanda oluşan eğilme gerilmeleri hesaplanmıştır. Buradan elde edilen gerilme değerleri emniyetli gerilme değerleriyle kıyaslanarak tava rafın taşıyabileceği maksimum yük tespit edilmiştir. Ayrıca analitik yöntemden elde edilen sonuçlar sonlu elemanlar yöntemiyle kıyaslanmış ve sonuçların birbiri ile uyumlu olduğu görülmüştür. tr_TR
dc.description.abstract In this study, determination of capacity for light duty shelf settled on pallet beam are considered. Carrying capacities of light duty shelf under the desired loading diemensions were determined both analytically and finite element analysis. It was assumed that light duty shelf was expose to distrubuted load on 2a x 2a region of shelf. It was assumed that distance between single forces is k and number of single forces was considered n in length of 2a. Afterwards, each value of single forces was found in terms of total force. Bending strength in each members of light duty shelf were calculated by finding moments occured each members. Obtained stress values are compared with safety stress values and maximum load capacity of light duty shelf is determined. Moreover, the results obtained from analytical method are compared with finite element results and the results are found to be compitable with each other. en_US
dc.identifier.uri http://hdl.handle.net/11527/18378
dc.language tr tr_TR
dc.publisher Teorik ve Uygulamalı Mekanik Türk Milli Komitesi tr_TR
dc.publisher Theoretical And Applied Mechanical Turkish National Committee en_US
dc.relation.ispartofseries 20. Ulusal Mekanik Kongresi tr_TR
dc.rights Kurumsal arşive yüklenen tüm eserler telif hakkı ile korunmaktadır. Bunlar, bu kaynak üzerinden herhangi bir amaçla görüntülenebilir, ancak yazılı izin alınmadan herhangi bir biçimde yeniden oluşturulması veya dağıtılması yasaklanmıştır. tr_TR
dc.rights All works uploaded to the institutional repository are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. en_US
dc.title Çelik Depo Raf Sistemlerinde Kullanılan Yatay Taşıyıcıya Oturan Tava Rafların Kapasitelerinin Analitik Ve Sonlu Elemanlar Yöntem tr_TR
dc.type Conference Paper en_US
dc.type Konferans Bildirisi tr_TR
Dosyalar
Orijinal seri
Şimdi gösteriliyor 1 - 1 / 1
thumbnail.default.alt
Ad:
074_senaysoy.pdf
Boyut:
863.83 KB
Format:
Adobe Portable Document Format
Açıklama
Lisanslı seri
Şimdi gösteriliyor 1 - 1 / 1
thumbnail.default.placeholder
Ad:
license.txt
Boyut:
3.16 KB
Format:
Plain Text
Açıklama