Mevcut Betonarme Bir Yapının Deprem Performansının Artımsal Eşdeğer Deprem Yükü Yöntemi İle Belirlenmesi Ve Güçlendirilmesi
| dc.contributor.advisor | Gündüz, A. Necmettin | |
| dc.contributor.author | Şenel, Abdül Cebbar Noyan | |
| dc.contributor.department | Deprem Mühendisliği | |
| dc.contributor.department | Earthquake Engineering | |
| dc.date | 2011 | |
| dc.date.accessioned | 2011-02-18 | |
| dc.date.accessioned | 2015-09-02T07:50:16Z | |
| dc.date.available | 2015-09-02T07:50:16Z | |
| dc.date.issued | 2011-02-18 | |
| dc.description | Tez (Yüksek Lisans) -- İstanbul Teknik Üniversitesi, Fen Bilimleri Enstitüsü, 2011 | |
| dc.description | Thesis (M.Sc.) -- İstanbul Technical University, Institute of Science and Technology, 2011 | |
| dc.description.abstract | Bu çalışmada, mevcut betonarme bir yapının deprem performansı, artımsal eşdeğer deprem yükü yöntemi kullanılarak incelenmiştir. Ele alınan yapı, İstanbul il sınırları içinde bulunan, 1990 yılında inşa edilmiş, altı katlı betonarme bir okul binasıdır. Doğrusal olmayan bu hesap yöntemi ile yapılan analiz sonucunda, yapının Deprem Bölgelerinde Yapılacak Binalar Hakkında Yönetmelik 2007’ye göre gerekli performans seviyesini sağlayamadığı belirlenmiştir. Deprem talep etkileri altında öngörülen performans hedeflerini sağlayamayan yapı, taşıyıcı sisteme betonarme perdelerin eklenmesi ve kolonların mantolanması ile güçlendirilmiştir. Güçlendirilmiş yapının deprem performansı, artımsal eşdeğer deprem yükü yöntemi kullanılarak yeniden belirlenmiştir. Yapılan güçlendirme işlemlerinden sonra yapının, Deprem Bölgelerinde Yapılacak Binalar Hakkında Yönetmelik 2007 de belirlenmiş olan performans hedeflerini sağladığı belirlenmiştir. Sonuç olarak, artımsal eşdeğer deprem yükü yöntemi kullanılarak, yapıların daha ekonomik olarak projelendirilmesinin, ve daha gerçekçi sonuçlar elde edilebilmesinin mümkün olduğu belirlenmiştir. | |
| dc.description.abstract | In this study an existent school building is evaluated for seismic performance by using the Incremental Equivalent Earthquake Load Method. The building examined, is a six storied reinforced concrete school structure built in 1990 which is located in Istanbul. According to the results of nonlinear analysis it is determined that the structure could not reach its necessary seismic performance targets defined in the Turkish Earthquake Code 2007. The structure that could not reach it is necessary performance targets under required seismic effects is strengthened by adding reinforced concrete walls and increasing the area of the column sections. The seismic performance of the strengthened structure is evaluated again by using the Incremental Equivalent Earthquake Load Method. It is determined that the strengthened structure reached its necessary performance targets defined in the Turkish Earthquake Code 2007. As a result, it is possible to design more economical projects and obtain more realistic results by using the Incremental Equivalent Earthquake Load Method. | |
| dc.description.degree | Yüksek Lisans | |
| dc.description.degree | M.Sc. | |
| dc.identifier.uri | http://hdl.handle.net/11527/8867 | |
| dc.publisher | Fen Bilimleri Enstitüsü | |
| dc.publisher | Institute of Science and Technology | |
| dc.rights | İTÜ tezleri telif hakkı ile korunmaktadır. Bunlar, bu kaynak üzerinden herhangi bir amaçla görüntülenebilir, ancak yazılı izin alınmadan herhangi bir biçimde yeniden oluşturulması veya dağıtılması yasaklanmıştır. | |
| dc.rights | İTÜ theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. | |
| dc.subject | Artımsal eşdeğer deprem yükü yöntemi | |
| dc.subject | Doğrusal olmayan analiz | |
| dc.subject | Deprem performansı | |
| dc.subject | İtme analizi | |
| dc.subject | Güçlendirme | |
| dc.subject | DBYBHY 2007 | |
| dc.subject | Equivalent Earthquake Load Method | |
| dc.subject | Nonlinear analysis | |
| dc.subject | Seismic performance | |
| dc.subject | Pushover analysis | |
| dc.subject | Strengthening | |
| dc.subject | The Turkish Earthquake Code 2007 | |
| dc.title | Mevcut Betonarme Bir Yapının Deprem Performansının Artımsal Eşdeğer Deprem Yükü Yöntemi İle Belirlenmesi Ve Güçlendirilmesi | |
| dc.title.alternative | Seismic Performance Determination And Strengthening Of An Existing Reinforced Concrete Building By Incremental Equivalent Earthquake Load Method | |
| dc.type | Master Thesis |