Rüzgâr Santrallerinin Güç Sistemlerine Etkilerinin İncelenmesi Ve Şebekeye uyumluluk Analizi

dc.contributor.advisor Kalenderli, Özcan tr_TR
dc.contributor.author Dumlu, Ferhat tr_TR
dc.contributor.authorID 10040307 tr_TR
dc.contributor.department Elektrik Mühendisliği tr_TR
dc.contributor.department Electrical Engineering en_US
dc.date 2015 tr_TR
dc.date.accessioned 2017-02-27T11:06:17Z
dc.date.available 2017-02-27T11:06:17Z
dc.date.issued 2015-10-22 tr_TR
dc.description Tez (Yüksek Lisans) -- İstanbul Teknik Üniversitesi, Fen Bilimleri Enstitüsü, 2015 tr_TR
dc.description Thesis (M.Sc.) -- İstanbul Technical University, Instıtute of Science and Technology, 2015 en_US
dc.description.abstract Rüzgâr enerjisinden elektrik üretimi son yıllarda oldukça hızlı bir artış göstermiştir. Şebeke işletmecileri, artan rüzgâr santrallerinin şebekede güvenilir, kaliteli  ve sürekli işletilmesi için yönetmelikler düzenlemekte ve bu yönetmeliklerde belirtilen şartların tüm rüzgâr santralleri için uygunluğunun tespitini gerekli kılmaktadırlar.  Bu tez çalışması kapsamında, rüzgâr türbinlerinin güç kalitesi karakteristikleri IEC 61400-21 standardına göre incelenmiş, rüzgâr santrallerinin bağlandığı şebeke üzerindeki güç kalitesi etkileri tanımlanmıştır. Rüzgâr gücü entegrasyonun yüksek olduğu ülkelerin ve Türkiye’nin şebeke yönetmeliklerinde belirtilen bağlantı koşulları değerlendirilmiş olup yorumlar ve öneriler sunulmuştur. Çalışma kapsamında, 48 MW kurulu gücünde, proje geliştirme çalışmaları devam eden bir rüzgâr santralinin, Türkiye şebeke yönetmeliğine uygunluğunun tespiti amacıyla sürekli ve geçici hal analizleri DigSILENT Power Factory güç sistemi analiz programı ile gerçekleştirilmiştir. Sürekli hal analizleri ile santralin yük akışı, kısa devre çalışmaları yapılmış olup, yönetmelikçe istenen reaktif güç kapasitesi tespit edilmiştir. Geçici hal analizleri kapsamında ise, rüzgâr santralinin arıza durumlarında sisteme bağlı kalabilme yetenekleri tespit edilmiş, arıza sonrası aktif güç tepkisinin uygunluğu şebeke yönetmeliklerinde belirtilen şartlar ile karşılaştırılmıştır. Ayrıca yönetmelikçe talep edilen reaktif güç desteği diğer bir ifade ile gerilim kontrol şartları da değerlendirilmiştir. tr_TR
dc.description.abstract In the recent years, there has been a considerable increase on electricity production from wind energy all over the world. The problems have started to arise in power system network after increase of wind energy installed power in the grid. The grid operators publish the regulations for the wind farms to be connected to power system in order to ensure safe operation in terms of power system security, stability and quality.  In this research study, the power quality characteristics of wind turbines were examined in accordance with IEC 61400-21 and power quality effects of wind farms on the network have been defined. The grid code connection requirements specifically related with wind farms integration to grid in Turkey and the other countries have been evaluated, the comments and proposals have been made. Besides, in the scope of study, steady state and dynamic-transient analysis of selected wind farm whose capacity is 48 MW, have been conducted with DigSILENT Power Factory power system analysis software in order to determine the compliance of a wind farm to the Turkish grid. The load flow and short circuit studies for the plant have been carried out by means of steady-state analysis and reactive power capacity has been determined to be in accordance with the regulations. In the scope of dynamic analysis, the fault ride through capability of wind farm has been investigated and the active power restoration capability after fault has been compared with grid code requirements. Also the voltage control selected wind farm has been evaluated in line with Turkish grid code. en_US
dc.description.degree Yüksek Lisans tr_TR
dc.description.degree M.Sc. en_US
dc.identifier.uri http://hdl.handle.net/11527/13159
dc.publisher Fen Bilimleri Enstitüsü tr_TR
dc.publisher Institute of Science and Technology en_US
dc.rights İTÜ tezleri telif hakkı ile korunmaktadır. Bunlar, bu kaynak üzerinden herhangi bir amaçla görüntülenebilir, ancak yazılı izin alınmadan herhangi bir biçimde yeniden oluşturulması veya dağıtılması yasaklanmıştır. tr_TR
dc.rights İTÜ theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. en_US
dc.subject Güç Kalitesi Rüzgar Gücü Entegrasyonu Rüzgar Gücü Şebeke Entegrasyonu Şebeke Uyumluluk Analizi tr_TR
dc.subject Power Quality Wind Power Integration Wind power Grid Integration Grid Compliance Analysis en_US
dc.title Rüzgâr Santrallerinin Güç Sistemlerine Etkilerinin İncelenmesi Ve Şebekeye uyumluluk Analizi tr_TR
dc.title.alternative Investigation Of The Impacts Of Wind Farms Integration On Grid And Perform Grid Code Compliance Studies en_US
dc.type Master Thesis en_US
Dosyalar
Orijinal seri
Şimdi gösteriliyor 1 - 1 / 1
thumbnail.default.alt
Ad:
10040307.pdf
Boyut:
2.86 MB
Format:
Adobe Portable Document Format
Açıklama
Lisanslı seri
Şimdi gösteriliyor 1 - 1 / 1
thumbnail.default.placeholder
Ad:
license.txt
Boyut:
3.16 KB
Format:
Plain Text
Açıklama