Çelik Tüp İle Güçlendirilmiş Kolon Sarılma Bölgelerinin Davranışı

dc.contributor.advisor İlki, Alper tr_TR
dc.contributor.author Sarmanli, Cihangir tr_TR
dc.contributor.department Deprem Mühendisliği tr_TR
dc.contributor.department Earthquake Engineering en_US
dc.date 2005 tr_TR
dc.date.accessioned 2015-09-02T07:50:01Z
dc.date.available 2015-09-02T07:50:01Z
dc.description Tez (Yüksek Lisans) -- İstanbul Teknik Üniversitesi, Fen Bilimleri Enstitüsü, 2005 tr_TR
dc.description Thesis (M.Sc.) -- İstanbul Technical University, Institute of Science and Technology, 2005 en_US
dc.description.abstract Bu çalışmada, sabit eksenel yük ve tekrarlı eğilme etkilerine maruz kolon sarılma bölgelerinin güçlendirilmesi incelenmiştir. Çalışma kapsamında üretilen 6 adet kolon numune İstanbul Teknik Üniversitesi, İnşaat Fakültesi, Yapı ve Deprem Mühendisliği Laboratuarında denenmiştir. Numuneler, Türkiye’deki yapıların önemli bir bölümünde bulunan kusurları yansıtmak üzere düşük beton dayanımı, yetersiz enine donatı ve yetersiz bindirme boyuna sahip olarak üretilmiştir. Üretilen numuneler dikdörtgen enkesitli olup 20 x 30 cm boyutlarındadır. Numunelerin yarısının boyuna donatıları sürekli donatılı, diğer yarısı ise boyuna donatı çapının 40 katı kadar bindirmeli eklidir. Donatı detayları kesme göçmesi olmayacak şekilde düzenlenmiştir. Deneysel çalışmada, 4 adet numune referans numunesi, 2 adet numune ise dıştan dışa 23 x 32 cm boyutlu 4 mm et kalınlığında ve 96 cm uzunluğunda çelik tüp ve çelik tüp ile numune arasına doldurulan tamir harcı ile güçlendirilmiştir. Deneysel sonuçlar, süneklik, dayanım, rijitlik ve hasar oluşumu açısından değerlendirilmiştir Güçlendirilen numunelerde gerek dayanım gerekse süneklik açısından çok daha iyi bir performans görülmüştür. Ayrıca daha önce aynı deney düzeneği ile denenen farklı güçlendirme tekniği kullanılarak güçlendirilmiş numunelerin güçlendirme maliyetleri hesaplanmış ve performanslarıyla maliyetleri arasında bir ilişki kurulmuştur. tr_TR
dc.description.abstract In this study, the behavior of retrofitted column confinement zone subjected to constant axial and reversed cyclic lateral loads is examined. Experimental study carried out in ITU laboratories. Specimens had a rectangular cross section of 20 x 30 cm. Three of the specimens had continuous longitudinal reinforcement bars and other three of the specimens had inadequate lap splice length. All of the specimen reinforcement details were designed against a collapse in shear failure. All specimens had deficiencies as inadequate transverse reinforcement, inadequate lap splices and low concrete quality to represent most of the existing structures in Turkey. Longitudinal reinforcing bars of the half specimens were continuous, while the others had lap-splices of 40xdiameter of longitudinal bars. All of the specimens were reinforced such that shear failure would be avoided. In experimental work four specimens were testeds as referance specimens that two of them had continuous longitudinal reinforcement bar and the other two had inadequate lap splice lenght. The remaining two specimens were retrofitted with steel jackets having a rectangular cross section of 23 x 32 cm and 96 cm of length and 4mm of thickness. The test results were evaluated in terms of strength, ductility, energy dissipation, rigidity and damage development. Behaviour of the specimens were positively improved with the retrofitting technique in terms of ductility and energy dissipation. The relation between performance and cost of experiments with different types of retrofitting techniques in the same experiment plan were also calculated. In this way retrofitting techniques evaluated in terms of performance and cost. en_US
dc.description.degree Yüksek Lisans tr_TR
dc.description.degree M.Sc. en_US
dc.identifier.uri http://hdl.handle.net/11527/8791
dc.publisher Fen Bilimleri Enstitüsü tr_TR
dc.publisher Institute of Science and Technology en_US
dc.rights İTÜ tezleri telif hakkı ile korunmaktadır. Bunlar, bu kaynak üzerinden herhangi bir amaçla görüntülenebilir, ancak yazılı izin alınmadan herhangi bir biçimde yeniden oluşturulması veya dağıtılması yasaklanmıştır. tr_TR
dc.rights İTÜ theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. en_US
dc.subject beton tr_TR
dc.subject dayanım tr_TR
dc.subject çelik tüp tr_TR
dc.subject süneklik tr_TR
dc.subject güçlendirme tr_TR
dc.subject concrete en_US
dc.subject strength en_US
dc.subject steel tube en_US
dc.subject ductility en_US
dc.subject retrofitted en_US
dc.title Çelik Tüp İle Güçlendirilmiş Kolon Sarılma Bölgelerinin Davranışı tr_TR
dc.title.alternative Behaviour Of Reinforced Concrete Coloums Retrofitted With Steel Tubes en_US
dc.type masterThesis en_US
Dosyalar
Orijinal seri
Şimdi gösteriliyor 1 - 1 / 1
thumbnail.default.alt
Ad:
2518.pdf
Boyut:
3.03 MB
Format:
Adobe Portable Document Format
Açıklama
Lisanslı seri
Şimdi gösteriliyor 1 - 1 / 1
thumbnail.default.placeholder
Ad:
license.txt
Boyut:
3.14 KB
Format:
Plain Text
Açıklama