Uzaysal Duzenlileştirmenin Dinamik Pet Parametre Kestirimlerine Olan Etkisi

dc.contributor.advisorBayram, İlker
dc.contributor.authorAlak, Sahra
dc.contributor.authorID10038742
dc.contributor.departmentElektronik ve Haberleşme Mühendisligi
dc.contributor.departmentElectronic and Communication Engineering
dc.date2015
dc.date.accessioned2017-02-27T11:08:44Z
dc.date.available2017-02-27T11:08:44Z
dc.date.issued2015-10-22
dc.descriptionTez (Yüksek Lisans) -- İstanbul Teknik Üniversitesi, Fen Bilimleri Enstitüsü, 2015
dc.descriptionThesis (M.Sc.) -- İstanbul Technical University, Instıtute of Science and Technology, 2015
dc.description.abstractPozitron emisyon tomografisi (PET) tıbbi alanda kullanılan ve pozitron yayıcı radyonüklidlerin insan vücudundaki dağılımını üç boyutlu  olarak görüntüleyen tanısal bir nükleer tıp yöntemidir. Kanser, tümör, epilepsi, koroner arter, parkinson ve alzheimer gibi çeşitli hastalıkların klinik tanısında kullanılır. Bu çalışmada kullanılan raclopride izleyicisine uygun olan iki dokulu kompartıman modeli kullanılmıştır. Bu tezde oluşturulan alti farklı gürültülü imgeler için kinetik parametre tahmininin  uzaysal regülarizasyonda etkileri araştırılmıştır. Geliştirilen algoritmanın performansını değerlendirmek amacıyla, dört farklı uzaysal regülarizasyon kullanılarak parametrik görüntüler benzetim sonuçları elde edilmistir.  Uzaysal regülarizasyon uygulanmayan (NR), düşük uzaysal regülarizasyonu (LR), orta uzaysal regülarizasyonu (MR), yüksek uzaysal regülarizasyonu (HR) olmak uzere dört farklı uzaysal regülarizasyon parametreleri kullanılarak simülasyonlar yapılmıştır. Deneysel çalışmalardan sonra, her uzaysal regularizasyon türü için en iyi parametre değerleri bulunmuştur.Oluşan parametrik görüntülerden yanlılık , varyans katsayısı ve ortalama karesel hata  gibi istatiksel değerler farklı gürültü seviyeleri, iki farklı ilgili bölge ve dört farklı regülarizasyon parametreleri için bu değerler hesaplandı. Elde edilen zaman aktivite eğrisi ile model çıktısı kullanılarak hesaplanan bu değerleri en aza indirecek kinetik parametreleri bulmaktır. Gürültüye ve ya regülarizasyona dayalı kestirim hatalarına bakılarak çeşitli gürültü seviyelerinde ve farklı ilgili bölgeye göre uygun uzaysal regülarizasyon parametresinin bulmayı amaçlamaktadır.
dc.description.abstractPositron emission tomography (PET) is a medical imaging modality that allows a powerful tool for clinical diagnosis of various diseases such as cancer, tumor detection, epilepsy, coronary artery, parkinson and alzheimer. Different comportment models can be used according to complexity of the tissue is psychology. The purpose of the comportment models is to give information about the status of the tracer in different chemical situations or in different place like plasma, tissue. In this thesis, a comportment model with two tissues is used which is suitable for raclopride tracer. Kinetic parameter estimation of spatial regularization is not worked frequently in the literature. This work proposes a solution for different noise values according to the effects of spatial regularization on parametric images.  Simulations are run by using four different spatial regularization methods as no, low, medium and high spatial regularization. Analysis of parametric images shows that proper selection of the regularization parameters is important for dynamic PET.
dc.description.degreeYüksek Lisans
dc.description.degreeM.Sc.
dc.identifier.urihttp://hdl.handle.net/11527/13237
dc.publisherFen Bilimleri Enstitüsü
dc.publisherInstitute of Science and Technology
dc.rightsİTÜ tezleri telif hakkı ile korunmaktadır. Bunlar, bu kaynak üzerinden herhangi bir amaçla görüntülenebilir, ancak yazılı izin alınmadan herhangi bir biçimde yeniden oluşturulması veya dağıtılması yasaklanmıştır.
dc.rightsİTÜ theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission.
dc.subjectPozitron Emisyon Tomografisi
dc.subjectKompartıman Model
dc.subjectKinetik Parametre Kestirimi
dc.subjectUzaysal Regülarizasyon Uygulanmayan
dc.subjectDüşük Uzaysal Regülarizasyonu
dc.subjectOrta Uzaysal Regülarizasyonu
dc.subjectYüksek Uzaysal Regülarizasyonu
dc.subjectPositron Emission Tomography
dc.subjectcompartman Model
dc.subjectKinetic Parameter Estimation
dc.subjectNo Spatial  regularization
dc.subjectLow Spatial Regularization
dc.subjectMedium Spatial Regularization
dc.subjectHigh Spatial Regularization
dc.titleUzaysal Duzenlileştirmenin Dinamik Pet Parametre Kestirimlerine Olan Etkisi
dc.title.alternativeEffects Of Spatial Regularization On Parameter Estimation For Dynamic Pet
dc.typeMaster Thesis

Dosyalar

Orijinal seri

Şimdi gösteriliyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
Ad:
10038742.pdf
Boyut:
1.39 MB
Format:
Adobe Portable Document Format

Lisanslı seri

Şimdi gösteriliyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
Ad:
license.txt
Boyut:
3.16 KB
Format:
Plain Text
Açıklama