Elektrik Dağıtım Sistemlerinin Güvenilirlik Analizi

dc.contributor.advisorÇağlar, Ramazan
dc.contributor.authorErsalıcı, Hüsnü
dc.contributor.authorID435301
dc.contributor.departmentElektrik Mühendisliği
dc.contributor.departmentElectrical Engineering
dc.date2012
dc.date.accessioned2012-07-03
dc.date.accessioned2015-05-12T12:47:16Z
dc.date.available2015-05-12T12:47:16Z
dc.date.issued2013-01-06
dc.descriptionTez (Yüksek Lisans) -- İstanbul Teknik Üniversitesi, Fen Bilimleri Enstitüsü, 2012
dc.descriptionThesis (M.Sc.) -- İstanbul Technical University, Institute of Science and Technology, 2012
dc.description.abstractBu tezde elektrik güç sistemleri içerisinde yer alan indirici trafo merkezi, iletim sistemi ve dağıtım sistemi için ayrı güvenilirlik değerlendirmeleri yapılmıştır. Bunlar içerisinden indirici trafo merkezi beş farklı bağlantı tipine göre değerlendirilmiştir. Daha sonra indirici trafo merkezlerinden güvenilirliği en düşük olan sistem, model alınan iletim sistemi ve elektrik enerjisinin tüketiciye ulaşan en bölümü olan dağıtım sisteminin tamamını kapsayacak şekilde güvenilirlik değerlendirmesi yapılmıştır. Analiz sonuçlarının değerlendirildiği son bölüm olan sonuç ve öneriler bölümünde ise ilk olarak önceki bölümde hesaplanan datalar ve performans indisleri doğrultusunda tüm sisteme ait güvenilirlik değerlendirmeleri yapılmıştır. Bu değerlendirmeler her bir dağıtım sistemi için ayrı ayrı hesaplanan performans indislerinin ABD’de elektrik kurumlarının sıklıkla kullandığı indislere ait ortalama değerler ile karşılaştırılmasını içermektedir. İlgili standartlara göre değerlendirmeler yapıldığında üç ayrı şebekenin de güvenilirliklerinin düşük olduğu gözlemlenmiştir.
dc.description.abstractIn this thesis study, separate reliability assessments were conducted for substation, transmission system and distribution system in electric power systems. Among these, substation relieability was evaluated according to five different connection types. Then, reliability evaluation was performed for the system with the lowest reliability among the substations in such a way to include the modeled transmission system and the entire distribution system which constitutes the final part of the electric energy offered to the consumers. In the section of result and suggestions, where analysis results were discussed, reliability evaluations were performed for the entire system according to the data and performance indexes calculated in the previous section. These evaluations included the comparison of performance indexes which were separately calculated for each distribution system with the mean values of the indexes electric institutions frequently used in the USA. Evaluations performed according to the related standards revealed that all three networks had low reliability.
dc.description.degreeYüksek Lisans
dc.description.degreeM.Sc.
dc.identifier.urihttp://hdl.handle.net/11527/1316
dc.publisherFen Bilimleri Enstitüsü
dc.publisherInstitute of Science and Technology
dc.rightsİTÜ tezleri telif hakkı ile korunmaktadır. Bunlar, bu kaynak üzerinden herhangi bir amaçla görüntülenebilir, ancak yazılı izin alınmadan herhangi bir biçimde yeniden oluşturulması veya dağıtılması yasaklanmıştır.
dc.rightsİTÜ theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission.
dc.subjectGüvenilirlik analizi
dc.subjectDağıtım sistemleri
dc.subjectİndirici merkez
dc.subjectReliability analysis
dc.subjectDistribution system
dc.subjectSubstation
dc.titleElektrik Dağıtım Sistemlerinin Güvenilirlik Analizi
dc.title.alternativeReliability Analysis In The Electric Distribution Systems
dc.typeMaster Thesis

Dosyalar

Orijinal seri

Şimdi gösteriliyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
Ad:
12747.pdf
Boyut:
2.24 MB
Format:
Adobe Portable Document Format

Lisanslı seri

Şimdi gösteriliyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
Ad:
license.txt
Boyut:
3.14 KB
Format:
Plain Text
Açıklama