Ayarlı Kütle Sönümleyicili Ve Viskoz Sönümleyicili Yapılarda Karma Bir Pasif Kontrol Uygulaması

dc.contributor.author Çetin, Hüseyin tr_TR
dc.contributor.author Öztürk, Baki tr_TR
dc.date 2017 tr_TR
dc.date.accessioned 2020-06-22T17:01:20Z
dc.date.available 2020-06-22T17:01:20Z
dc.date.issued 2017
dc.description Konferans Bildirisi-- İstanbul Teknik Üniversitesi, Teorik ve Uygulamalı Mekanik Türk Milli Komitesi, 2017 tr_TR
dc.description Conference Paper -- İstanbul Technical University, Theoretical and Applied Mechanical Turkish National Committee, 2017 en_US
dc.description.abstract Son yıllarda depreme dayanıklı yapı tasarımı konusunda geliştirilen pasif sistemlerin tek başlarına yapılarda, deprem ve rüzgâr enerjilerini sönümledikleri görülmüştür. Özellikle ayarlı kütle sönümleyicilerin (TMD) rüzgâr etkilerine karşı daha etkili oldukları, viskoz sönümleyicilerinde (VD) depremlerde iyi performans sergiledikleri bilinmektedir. Bu çalışma, bu iki farklı pasif sönümleyici sisteminin bir arada en uygun kullanımına odaklanmıştır. Hem ayarlı kütle sönümleyicilerin hem de viskoz sönümleyicilerin olduğu karma bir sistem amaçlanmıştır. Biri tepe de, diğeri bir ara katta olmak üzere iki tane ayarlı kütle sönümleyiciye ve katlarda viskoz sönümleyicilere sahip bir kayma çerçevesinde, optimum sönümleyici dağılımı araştırılmıştır. Optimizasyon probleminde ayarlı kütle sönümleyicilerin sönüm ve rijitlik katsayısı %3 TMD kütle oranı altında optimize edilmiştir. TMD parametrelerinin optimizasyonunda literatürde verilen ampirik denklemler kullanılmıştır. Çalışmada hedeflenen, katlar arası rölatif deplasman oranının izin verilebilir seviyede olmasıdır. Kullanılan optimizasyon algoritmasında katlar arası göreceli deplasmanlar belli seviyede tutulurken, bir hedef sönüm oranına da ulaşılmaktadır. Sonuç olarak bu karma pasif kontrol sistemi hem eklenen sönümleyici miktarını, hem de kat deplasman ve katlar arası rölatif deplasmanı azaltmaktadır. tr_TR
dc.description.abstract In recent years, the passive systems developed for the structural design have been seen to have extinguished earthquake and wind energies by themselves. It is known that particularly tuned mass dampers (TMD) are more effective against wind effects, and perform well in viscous dampers (VD) in earthquakes. This study focuses on the optimal use of these two different passive damping systems together. A hybrid system with both a set mass damper and a set viscous damper is aimed. An optimal damper distribution was investigated in a shear frame with two set mass dampers, one at the top, the other at the intermediate storey, and viscous dampers at the floors. The damping and stiffness coefficients of the mass dampers set in the optimization problem are optimized under the 3% TMD mass ratio. In the optimization of TMD parameters, the empirical equations given in literature are used. The targeted rate of relative displacement between floors is the allowable level. In the optimization algorithm used, while the relative displacements between the floors are kept at a certain level, a target damping ratio is also reached. As a result, this mixed passive control system has been effective in reducing viscous damper quantity as well as effectively reducing displacements and inter-storey drifts. en_US
dc.identifier.uri http://hdl.handle.net/11527/18403
dc.language tr tr_TR
dc.publisher Teorik ve Uygulamalı Mekanik Türk Milli Komitesi tr_TR
dc.publisher Theoretical And Applied Mechanical Turkish National Committee en_US
dc.relation.ispartofseries 20. Ulusal Mekanik Kongresi tr_TR
dc.rights Kurumsal arşive yüklenen tüm eserler telif hakkı ile korunmaktadır. Bunlar, bu kaynak üzerinden herhangi bir amaçla görüntülenebilir, ancak yazılı izin alınmadan herhangi bir biçimde yeniden oluşturulması veya dağıtılması yasaklanmıştır. tr_TR
dc.rights All works uploaded to the institutional repository are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. en_US
dc.title Ayarlı Kütle Sönümleyicili Ve Viskoz Sönümleyicili Yapılarda Karma Bir Pasif Kontrol Uygulaması tr_TR
dc.type Conference Paper en_US
Dosyalar
Orijinal seri
Şimdi gösteriliyor 1 - 1 / 1
thumbnail.default.alt
Ad:
102_cetin.pdf
Boyut:
971.12 KB
Format:
Adobe Portable Document Format
Açıklama
Lisanslı seri
Şimdi gösteriliyor 1 - 1 / 1
thumbnail.default.placeholder
Ad:
license.txt
Boyut:
3.16 KB
Format:
Plain Text
Açıklama