AISC 360-10 Ve Türk Deprem Yönetmeliği (DBYBHY, 2007)' ne Göre Çelik Yapıların Tasarımı
AISC 360-10 Ve Türk Deprem Yönetmeliği (DBYBHY, 2007)' ne Göre Çelik Yapıların Tasarımı
dc.contributor.author | Ülker, Mustafa | tr_TR |
dc.contributor.author | Savaş, Sedat | tr_TR |
dc.date.accessioned | 2017-06-16T09:50:53Z | |
dc.date.available | 2017-06-16T09:50:53Z | |
dc.date.issued | 2015 | tr_TR |
dc.description | Konferans Bildirisi -- Teorik ve Uygulamalı Mekanik Türk Milli Komitesi, 2015 | tr_TR |
dc.description | Conference Paper -- Theoretical and Applied Mechanical Turkish National Committee, 2015 | en_US |
dc.description.abstract | Bu çalışmada, Amerikan AISC (American Institute of Steel Construction) 360-10 ve Türk Deprem yönetmeliği DBYBHY (Deprem Bölgelerinde Yapılan Binalar Hakkında Yönetmelik) 2007’ ye göre çelik yapıların tasarım kuralları araştırılmış ve irdelenmiştir. Sayısal uygulama olarak, altı katlı çelik bir yapının tasarımı “bir doğrultuda süneklik düzeyi yüksek çerçeveli, diğer doğrultuda süneklik düzeyi yüksek dışmerkez çapraz perdeli sistem” her iki yönetmelik esaslarıyla yapılmıştır. Araştırmada, AISC 360-10 yönetmeliğine göre tasarım ilkeleri, LRFD ve ASD ‘ye göre hesap esasları, kesitlerin sınıflandırılması konuları etraflıca araştırılmıştır. Çelik yapının yapısal analizi SAP2000 programı ile gerçekleştirilmiştir. Analizde yükleme kombinezonu olarak AISC 306-10 yönetmeliğinin yükleme kombinezonları alınmıştır. | tr_TR |
dc.description.abstract | The rules for the design of steel structures in accordance with the American AISC 360-10 and Turkish Seismic Code (TSC-DBYYHY 2007) were investigated and studied in this study. A structural system that has “high ductile frame in one direction and high ductile eccentrically braced frame in other direction” was designed with regarding the principals of both codes. Principals of design in accordance with the AISC 360-10, fundamentals of LRFD and ASD, and classification of sections are deeply investigated in this investigation. The design of a six-storey steel structure that has “high ductile frame in one direction and high ductile eccentrically braced frame in other direction” is presented in this study. The structural analysis was performed with using SAP2000 structural analysis software. Loading combinations that are defined in AISC 360-10 are used in the structural analysis. | en_US |
dc.identifier.uri | http://hdl.handle.net/11527/14575 | |
dc.publisher | Teorik ve Uygulamalı Mekanik Türk Milli Komitesi | tr_TR |
dc.publisher | Theoretical and Applied Mechanical Turkish National Committee | en_US |
dc.rights | Kurumsal arşive yüklenen tüm eserler telif hakkı ile korunmaktadır. Bunlar, bu kaynak üzerinden herhangi bir amaçla görüntülenebilir, ancak yazılı izin alınmadan herhangi bir biçimde yeniden oluşturulması veya dağıtılması yasaklanmıştır. | tr_TR |
dc.rights | All works uploaded to the institutional repository are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. | en_US |
dc.title | AISC 360-10 Ve Türk Deprem Yönetmeliği (DBYBHY, 2007)' ne Göre Çelik Yapıların Tasarımı | tr_TR |
dc.type | Conference Paper | en_US |
dc.type | Konferans Bildirisi | tr_TR |