Tomosentez İçin İki Farklı Işın İzleme Algoritmasının Karşılaştırılması

dc.contributor.advisor Kamaşak, Mustafa Ersel tr_TR
dc.contributor.author Can, Emine tr_TR
dc.contributor.authorID 412544 tr_TR
dc.contributor.department Biyomedikal Mühendisliği tr_TR
dc.contributor.department Biomedical Engineering en_US
dc.date 2011 tr_TR
dc.date.accessioned 2011-09-07 tr_TR
dc.date.accessioned 2015-04-21T12:00:35Z
dc.date.available 2015-04-21T12:00:35Z
dc.date.issued 2011-09-12 tr_TR
dc.description Tez (Yüksek Lisans) -- İstanbul Teknik Üniversitesi, Fen Bilimleri Enstitüsü, 2011 tr_TR
dc.description Thesis (M.Sc.) -- İstanbul Technical University, Institute of Science and Technology, 2011 en_US
dc.description.abstract Meme kanseri dünya çapında önemli bir sağlık sorunudur. Kadınlarda ölüm nedenleri arasında ilk sırada yer alır. Mamografinin film teknolojisinden sayısal hale geçişi meme kanseri teşhisine bir çok avantaj sağlamıştır. Özellikle yeni sayısal panel algılayıcıların ortaya çıkması ile görüntü kalitesini artıracak gibi yeni algoritmaların uygulanabilmesi mümkün hale gelmiştir. Bu çalışmanın amacı görüntü elde etmede yeni bir ışın izleme algoritması oluşturmak ve sonuçlarını Siddon’un bilinen ışın izleme modeli ile karşılaştırmaktır. Deneyler iki boyutlu görüntüler için uygulanmıştır ve oluşturulan algoritmalar üç boyutlu görüntülere de kolaylıkla uyarlanabilecek şekilde tasarlanmıştır. Tüm bu proje ilk olarak meme tomosentezinde temel problemlerden biri olan sınırlı açı projeksiyonundan ilham almıştır. Bu nedenle deneyler sınırlı açı projeksiyon koşulunun sonuçlarını da kapsar. Tüm algoritmalar ve deneyler Matlab ile programlanmış ve gerçeklenmiştir. Etkili sonuçlar elde edilmesine rağmen yeni geliştirilen algoritmanın yüksek frekanslarda görüntünün kontrastını azalttığı gözlemlenmiştir. Aynı zamanda, ışın izleme algoritmaları hızlı işlem yapacak şekilde tasarlanmış olmasına rağmen kullanılan cebirsel görüntü elde etme algoritmasının tekrarlı yapısının işlemin toplam süresini büyük boyutlu görüntüler ile kolay çalışamayacak şekilde uzattığı gözlemlenmiştir. tr_TR
dc.description.abstract Breast cancer is a major health problem worlwide which comes in the first rank as a cause of death in women. In breast cancer diagnosis, the transition of mammography from screen-film to digital form has made many advantages available. Especially with the introduction of new digital flat panel detectors, new algorithms which improves image quality became available. The objective of this study is to form a new ray tracing algorithm for image reconstruction and compare the reconstructed image quality with the results of known ray tracing model of Siddon. Tomographic reconstruction is modelled with simultaneous algebraic reconstruction technique which is a way of reconstruction in tomosynthesis. The experiments are applied to two dimensional images and also the algorithm is designed in the form that it can be easily modified to three dimensional detection. The whole project is firstly inspired by limited view of angle which is one of the main problems in breast tomosynthesis. Thus the experiments also consider the results of limited angle of view projection case. All of the algorithms and experiments are programmed and simulated with Matlab. Although efficacious results are obtained with both of the algorithms, a drawback with the newly developed model is the lack of contrast in low frequencies. In addition it is realized that even the ray tracing algorithms are fast, the iterative property of algebraic reconstruction technique makes the process ever time consuming which does not let to work with images in larger size. en_US
dc.description.degree Yüksek Lisans tr_TR
dc.description.degree M.Sc. en_US
dc.identifier.uri http://hdl.handle.net/11527/821
dc.publisher Fen Bilimleri Enstitüsü tr_TR
dc.publisher Institute of Science and Technology en_US
dc.rights İTÜ tezleri telif hakkı ile korunmaktadır. Bunlar, bu kaynak üzerinden herhangi bir amaçla görüntülenebilir, ancak yazılı izin alınmadan herhangi bir biçimde yeniden oluşturulması veya dağıtılması yasaklanmıştır. tr_TR
dc.rights İTÜ theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. en_US
dc.subject Tomosentez tr_TR
dc.subject Cebirsel görüntü elde etme teknikleri tr_TR
dc.subject Işın izleme tr_TR
dc.subject Tomosynthesis en_US
dc.subject Algebraic reconstruction techniques en_US
dc.subject Ray tracing en_US
dc.title Tomosentez İçin İki Farklı Işın İzleme Algoritmasının Karşılaştırılması tr_TR
dc.title.alternative Comparison Of Two Different Ray Tracing Algorithms For Tomosynthesis en_US
dc.type Thesis en_US
dc.type Tez tr_TR
Dosyalar
Orijinal seri
Şimdi gösteriliyor 1 - 1 / 1
thumbnail.default.alt
Ad:
12038.pdf
Boyut:
3.07 MB
Format:
Adobe Portable Document Format
Açıklama
Lisanslı seri
Şimdi gösteriliyor 1 - 1 / 1
thumbnail.default.placeholder
Ad:
license.txt
Boyut:
3.14 KB
Format:
Plain Text
Açıklama