İnterferometrik Fiber Optik Jiroskop

dc.contributor.advisor Bir, Atilla tr_TR
dc.contributor.author Sağlar, İsmet Faik tr_TR
dc.contributor.department Kontrol ve Otomasyon Mühendisliği tr_TR
dc.contributor.department Control and Otomation Engineering en_US
dc.date 2007 tr_TR
dc.date.accessioned 2015-06-15T17:03:04Z
dc.date.available 2015-06-15T17:03:04Z
dc.description Tez (Yüksek Lisans) -- İstanbul Teknik Üniversitesi, Fen Bilimleri Enstitüsü, 2007 tr_TR
dc.description Thesis (M.Sc.) -- İstanbul Technical University, Institute of Science and Technology, 2007 en_US
dc.description.abstract Bu çalışmada, Sagnac etkisine dayanan interferometrik fiber optik jiroskopların çalışma prensiplerinin öğrenilmesi yanında karşılaştırma amacıyla bir kaç adet prototip jiroskopun geliştirilmesi ve kalibrasyonunun yapılması amaçlanmıştır. İlk interferometrik fiber optik jiroskop 1976 yılında geliştirilmiş olmasına rağmen olgunluğa erişip kullanıma girmesi 1990’lı yılları bulmuştur. Şu anda kara, hava, deniz ve uzay uygulamalarında birincil ataletsel seyrüsefer sensörü olarak kullanılmaktadır. Yapılan çalışmanın amaçlarından bir diğeri de interferometrik fiber optik jiroskopun ülkemizde üretimi için bilgi birikimi ve altyapı oluşturmaktır. Geliştirilen jiroskopun kolay temin edilebilir komponentlerden oluşması tercih edilmiştir. Böylelikle, parça sıkıntısı çekilmeyecek ve kolay imal edilebilecektir. Laboratuarda inşa edilen iki adet interferometrik fiber optik jiroskopun ölçüm sonuçları birbirine yakın elde edilmiştir. Ayrıca bu sonuçların teorik hesaplara uygun olduğu da gözlenmiştir. Jiroskopların kalibrasyonu, ısıl testler için gerekli uygun ölçüm cihazları olmadan ve ortamın değişken sıcaklığında yapılmıştır. Optik ve elektronik bileşenlerin hiçbiri için ısıl stabilizasyon olmadan yapılan hassasiyet ölçümlerinde, sensörlerin en az 0.05 derece/saniye’lik dönüş hızlarını sorunsuz algılayabildiği gözlemlenmiştir. Bu hassasiyetin uygun paketleme, ısıl karakterizasyon, model tabanlı kompanzasyon, sayısal filtreleme ve hassas kalibrasyon yöntemlerinin uygulanmasıyla en az 0.01 derece/saniye’ye ulaşacağı öngörülmüştür ki, bu kısa menzilli taktik uygulamalar ile robotik seyrüsefer sistemleri için yeterli olmaktadır. tr_TR
dc.description.abstract In this study, acquisition of principles of interferometric fiber optic gyroscope based on Sagnac effect, along with development and calibration of more than one prototype gyroscopes for comparison is targeted. Although, first interferometric fiber optic gyroscope was developed in 1976, it was after 1990 for the fiber optic gyroscope to earn its maturity and be used. Now, it is used as a primary inertial navigation sensor in land, air, sea and space applications. Another purpose of this work is to constitute know-how and basis for manufacturing of interferometric fiber optic gyroscope in our country. Components of the developed gyroscopes were selected among easy supplied parts. In this way, component shortage will not be an issue and easy manufacturability is assured. Calibration results of the two interferometric fiber optic gyroscopes, which were constructed in laboratory, are obtained similar. Also these results are in accord with the theoretical calculations. Calibration of gyroscopes is done in varying ambient temperature conditions without appropriate devices required for thermal tests. According to sensitivity measurements performed, without any thermal stabilization for optic and electronic components, minimum 0.05 degrees per second rotation rate was easily sensed by both sensors. This sensitivity could easily be enhanced by the application of proper packaging, thermal characterization, model based compensation and precision calibration methods, to minimum 0.01 degrees per second which is suitable for short range tactical applications and robotic navigation systems. en_US
dc.description.degree Yüksek Lisans tr_TR
dc.description.degree M.Sc. en_US
dc.identifier.uri http://hdl.handle.net/11527/5246
dc.publisher Fen Bilimleri Enstitüsü tr_TR
dc.publisher Institute of Science and Technology en_US
dc.rights İTÜ tezleri telif hakkı ile korunmaktadır. Bunlar, bu kaynak üzerinden herhangi bir amaçla görüntülenebilir, ancak yazılı izin alınmadan herhangi bir biçimde yeniden oluşturulması veya dağıtılması yasaklanmıştır. tr_TR
dc.rights İTÜ theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. en_US
dc.subject Sagnac Etkisi tr_TR
dc.subject Fiber Optik Jiroskop tr_TR
dc.subject İnterferometre tr_TR
dc.subject Optik Fiber tr_TR
dc.subject Sagnac Effect en_US
dc.subject Fiber Optic Gyroscope en_US
dc.subject Interferometer en_US
dc.subject Optical Fiber en_US
dc.title İnterferometrik Fiber Optik Jiroskop tr_TR
dc.title.alternative Interferometric Fiber Optic Gyroscope en_US
dc.type Master Thesis en_US
Dosyalar
Orijinal seri
Şimdi gösteriliyor 1 - 1 / 1
thumbnail.default.alt
Ad:
7596.pdf
Boyut:
1.52 MB
Format:
Adobe Portable Document Format
Açıklama
Lisanslı seri
Şimdi gösteriliyor 1 - 1 / 1
thumbnail.default.placeholder
Ad:
license.txt
Boyut:
3.16 KB
Format:
Plain Text
Açıklama