Yayın:
Investigation of lead contents in lipsticks by solid sampling high resolution continuum source electrothermal atomic absorption spectrometry

dc.contributor.authorGunduz, Sema
dc.contributor.authorAkman, Suleyman
dc.date.accessioned2026-01-25T01:28:52Z
dc.date.issued2013-02-01
dc.description.abstractIn this study, the lead contents of different kinds of lipsticks were determined by solid sampling high resolution continuum source electrothermal atomic absorption spectrometry (SS-HR-CS ET AAS) and the results were compared with those obtained after microwave-assisted acid digestion of the samples. The experimental parameters for solid sampling such as the maximum amount of sample on the platforms of solid autosampler, graphite furnace program were optimized. Samples were directly loaded on the platforms of solid autosampler between 0.25 and 2.0mg and lead was determined applying 800 °C for pyrolysis and 2100 °C for atomization. Under optimized conditions, interference-free determination could be performed using aqueous standards. The LOD and the characteristic mass were 21.3 and 12.6 pg, respectively. The lead in the same lipstick samples was determined after microwave-assisted acid digestion and compared with those found by solid sampling. Mostly, there was no significant difference between the lead concentrations found by the two techniques. The lead in 25 lipstick samples with different properties were 0.11-4.48 ng mg(-1) which were not significantly different from those (<0.026-7.19 ng mg(-1)) reported by FDA for around 400 samples.
dc.description.urihttps://doi.org/10.1016/j.yrtph.2012.10.009
dc.description.urihttps://pubmed.ncbi.nlm.nih.gov/23099440
dc.description.urihttps://dx.doi.org/10.1016/j.yrtph.2012.10.009
dc.identifier.doi10.1016/j.yrtph.2012.10.009
dc.identifier.endpage37
dc.identifier.issn0273-2300
dc.identifier.openairedoi_dedup___::42c59896142e32a6e6b2e03c7d93b707
dc.identifier.orcid0000-0002-8625-783x
dc.identifier.startpage34
dc.identifier.urihttps://hdl.handle.net/11527/41301
dc.identifier.volume65
dc.language.isoeng
dc.publisherElsevier BV
dc.relation.ispartofRegulatory Toxicology and Pharmacology
dc.rightsCLOSED
dc.subjectLead
dc.subjectLimit of Detection
dc.subjectSpectrophotometry, Atomic
dc.subjectTemperature
dc.subjectHumans
dc.subjectCosmetics
dc.subjectLip
dc.titleInvestigation of lead contents in lipsticks by solid sampling high resolution continuum source electrothermal atomic absorption spectrometry
dc.typeArticle
dspace.entity.typePublication

Dosyalar

Koleksiyonlar