Yayın:
Investigating the structural damage in Hatay province after Kahramanmaraş-Türkiye earthquake sequences

dc.contributor.authorAltunsu, Elif
dc.contributor.authorGüneş, Onur
dc.contributor.authorÖztürk, Sezer
dc.contributor.authorSorosh, Shokrullah
dc.contributor.authorSarı, Ali
dc.contributor.authorBeeson, Saadet Toker
dc.contributor.ituauthorSarı, Ali
dc.date.accessioned2026-01-24T14:36:14Z
dc.date.issued2024-03-01
dc.description.abstractOn February 6, 2023, two heavy earthquakes with moment magnitudes (MW) of 7.7 and 7.6 hit the Kahramanmaraş region in southeast Türkiye. Aftershocks of moment magnitude of 6 occurred consequently. These earthquakes affected more than 14 million people, and caused severe damage to civil infrastructure including buildings, government offices, religious buildings, dams, bridges, airports, and roads. After the earthquakes, a group of researchers visited the Hatay province to assess the response of buildings. Hatay was one of the most heavily affected cities in the region. The researchers gathered data on damaged reinforced concrete buildings, steel structures, as well as masonry buildings. This paper focuses on discussing the findings and analyzing the gathered data from reinforced concrete buildings and steel structures. A wide variety of issues that resulted in heavy damage or, in some cases, complete collapse of the buildings are discussed. These problems include construction mistakes such as insufficient shear reinforcements, neglected corrosion, utilizing low-quality concrete, insufficient development length in flexural reinforcements, and strong beam- weak column failure. In addition, various design errors including excessive torsional response of buildings, rigidity difference in two orthogonal directions of east–west and north–south of the building plan, pounding effect, short column failure, and development of weak and soft stories are described using gathered pictorial data. Finally, recommendations were made, and conclusions were drawn based on previous experimental and numerical studies of the seismic behavior of buildings as well as Turkish Building Earthquake Code (TBEC- 2018) requirements. © 2023 Elsevier Ltd
dc.description.urihttps://doi.org/10.1016/j.engfailanal.2023.107857
dc.description.urihttps://hdl.handle.net/20.500.12831/19551
dc.description.urihttps://aperta.ulakbim.gov.tr/record/269120
dc.identifier.doi10.1016/j.engfailanal.2023.107857
dc.identifier.issn1350-6307
dc.identifier.openairedoi_dedup___::05e2d78a7d32b30e8561bfb180eefb6a
dc.identifier.orcid0000-0002-1998-3014
dc.identifier.orcid0000-0003-2165-3687
dc.identifier.orcid0000-0003-2826-9696
dc.identifier.orcid0000-0002-6888-1276
dc.identifier.startpage107857
dc.identifier.urihttps://hdl.handle.net/11527/33475
dc.identifier.volume157
dc.language.isoeng
dc.publisherElsevier BV
dc.relation.ispartofEngineering Failure Analysis
dc.rightsOPEN
dc.sdg.typeGoal 11: Sustainable Cities and Communities
dc.sdg.typeGoal 13: Climate Action
dc.subjectEarthquake
dc.subjectConcrete construction
dc.subjectReinforced concrete buildings
dc.subjectGround motion
dc.subjectStructural analysis
dc.subjectKahramanmaraş earthquakes
dc.subjectStructural failure
dc.subjectFailure (mechanical)
dc.subjectFracture mechanics
dc.subjectEarthquakes
dc.subjectColumn failure
dc.subjectKahramanmaraş earthquake
dc.subjectGround-motion
dc.subjectCivil infrastructures
dc.subjectStructural damages
dc.subjectBridges
dc.subjectMoment magnitudes
dc.subjectCorrosion
dc.subjectReinforced concrete
dc.subjectSeismic effect
dc.subjectConcrete buildings
dc.subjectSteel structures
dc.subjectStructural integrity
dc.subjectEarthquake sequences
dc.titleInvestigating the structural damage in Hatay province after Kahramanmaraş-Türkiye earthquake sequences
dc.typeArticle
dspace.entity.typePublication
person.identifier.orcid0000-0002-6888-1276

Dosyalar

Koleksiyonlar