Yayın:
The Improved X-ray Detector (iXRD) on Sharjah-Sat-1, design principles, tests and ground calibration

dc.contributor.authorKalemci, Emrah
dc.contributor.authorAli M. Altıngün
dc.contributor.authorBozkurt, Ayhan
dc.contributor.authorA. R. Aslan
dc.contributor.authorYalçın, Refik
dc.contributor.authorGökalp, Kaya
dc.contributor.authorVeziroğlu, Kaan
dc.contributor.authorFernini, Ilias
dc.contributor.authorA. Manousakis
dc.contributor.authorYaşar, Ali
dc.contributor.authorDiba, Milad
dc.contributor.authorKarabulut, Boğaç
dc.contributor.authorÇatal, Egemen
dc.contributor.authorÖztekin, Onur
dc.contributor.ituauthorAslan, Alim Rüstem
dc.date.accessioned2026-01-26T01:17:14Z
dc.date.issued2022-07-19
dc.description.abstractAbstract The ixRD is the primary science payload on Sharjah-Sat-1, a 3U CubeSat expected to be launched in Q4, 2022. Its main scientific goal is monitoring bright hard X-ray sources and transients in 20 - 200 keV band. The iXRD consists of a CdZnTe crystal (6.45 cm2 area, 5 mm thickness), a Tungsten collimator with square holes with an opening angle of 4.26o, readout and control electronics and power circuitry, a back-shield and mechanical structures. Some of the design elements of iXRD have been inherited from the XRD on BeEagleSat with significant improvements in terms of collecting area, X-ray background and electronic noise. In this article, the design of the iXRD is discussed in detail taking into account mechanical, electronics, control software and data handling aspects. Its expected performance is determined after ground calibration. Depending on the pixel size, the energy resolution is 4 - 7 keV at 60 keV and the minimum detectable energy is 19 - 23 keV.
dc.description.urihttps://doi.org/10.21203/rs.3.rs-1846346/v1
dc.description.urihttps://doi.org/10.1007/s10686-023-09890-z
dc.description.urihttps://dx.doi.org/10.60692/31t3d-n1j66
dc.description.urihttps://dx.doi.org/10.60692/xxksy-dme56
dc.description.urihttps://dx.doi.org/10.60692/n90fm-6jn81
dc.description.urihttps://dx.doi.org/10.60692/3pv7e-sp603
dc.description.urihttps://doi.org/https://doi.org/10.1007/s10686-023-09890-z
dc.identifier.doi10.21203/rs.3.rs-1846346/v1
dc.identifier.eissn1572-9508
dc.identifier.endpage116
dc.identifier.issn0922-6435
dc.identifier.openairedoi_dedup___::b920d8fffc1f93f3c7fc70f735815920
dc.identifier.orcid0000-0002-9461-4948
dc.identifier.orcid0000-0003-4806-951x
dc.identifier.orcid0000-0003-0651-2181
dc.identifier.startpage99
dc.identifier.urihttps://hdl.handle.net/11527/55759
dc.identifier.volume56
dc.publisherResearch Square Platform LLC
dc.relation.ispartofExperimental Astronomy
dc.rightsOPEN
dc.sdg.typeGoal 7: Affordable and Clean Energy
dc.subjectX-ray detector
dc.subjectAstronomy
dc.subjectBiomedical Engineering
dc.subjectDual-Energy Computed Tomography
dc.subjectFOS: Medical engineering
dc.subjectQuantum mechanics
dc.subjectEngineering
dc.subjectCollimator
dc.subjectInfrared Detector Technologies
dc.subjectFOS: Electrical engineering, electronic engineering, information engineering
dc.subjectNeutron Imaging and Analysis Techniques
dc.subjectOptoelectronics
dc.subjectElectrical and Electronic Engineering
dc.subjectComputer network
dc.subjectRadiation
dc.subjectNetwork packet
dc.subjectPhysics
dc.subjectCubeSat
dc.subjectDetector
dc.subjectOptics
dc.subjectInfrared Detectors
dc.subjectComputer science
dc.subjectPayload (computing)
dc.subjectScintillation Detector Technology
dc.subjectPhysics and Astronomy
dc.subjectSatellite
dc.subjectElectrical engineering
dc.subjectPhysical Sciences
dc.subjectCalibration
dc.subjectElectronics
dc.titleThe Improved X-ray Detector (iXRD) on Sharjah-Sat-1, design principles, tests and ground calibration
dc.typeOther
dspace.entity.typePublication
person.identifier.orcid0000-0003-0651-2181

Dosyalar