Yayın: Evaluation of in-pipe turbine performance for turbo solenoid valve system
| dc.contributor.author | Mutlu, Y. | |
| dc.contributor.author | Çakan, M. | |
| dc.date.accessioned | 2026-01-25T05:29:46Z | |
| dc.date.issued | 2018-01-01 | |
| dc.description.abstract | This study is related to the newly developed and patented turbo solenoid turbine system. In this context, a numerical study was conducted on turbines with Darrieus, Gorlov and Lucid® configurations. As a result of the tests made on turbines with a NACA0018 aerofoil profile, the Lucid® turbine produced the highest moment and also highest pressure loss. Although a 10° twisted aerofoil Gorlov turbine produced 31.3% less moment than the Lucid® turbine, it also caused 51.4% less pressure loss. Also, it was observed that a Darrieus turbine with NACA0021 profile produced 1.5% less moment and 3.3% more pressure loss than a NACA0018 profile and turbine with NACA0015 profile, which produced 9% more moment and 1.4% more pressure loss than NACA0018. On the performance impact studies of the aerofoil twist angle, 20° twisted Gorlov turbines produced 19.1% more moment and 5.5% less pressure loss than a 10° twisted aerofoil turbine. Finally, a 20° twisted Gorlov turbine with NACA0015 aerofoil profile was analyzed. Following the studies, it was observed that the 20° twisted Gorlov turbine with NACA0015 aerofoil profile gave the best result by creating a 49.3% less pressure loss, in spite of only producing 4.7% less moment than the Lucid® turbine. | |
| dc.description.uri | https://doi.org/10.1080/19942060.2018.1506364 | |
| dc.description.uri | https://www.tandfonline.com/doi/pdf/10.1080/19942060.2018.1506364?needAccess=true | |
| dc.description.uri | https://doaj.org/article/40c5b3f839e8418eacf2b816303cd161 | |
| dc.description.uri | https://dx.doi.org/10.1080/19942060.2018.1506364 | |
| dc.identifier.doi | 10.1080/19942060.2018.1506364 | |
| dc.identifier.eissn | 1997-003X | |
| dc.identifier.endpage | 634 | |
| dc.identifier.issn | 1994-2060 | |
| dc.identifier.openaire | doi_dedup___::6cc284b1797c93c8fb92ec4af9554b59 | |
| dc.identifier.orcid | 0009-0002-9790-5465 | |
| dc.identifier.startpage | 625 | |
| dc.identifier.uri | https://hdl.handle.net/11527/46973 | |
| dc.identifier.volume | 12 | |
| dc.language.iso | eng | |
| dc.publisher | Informa UK Limited | |
| dc.relation.ispartof | Engineering Applications of Computational Fluid Mechanics | |
| dc.rights | OPEN | |
| dc.sdg.type | Goal 7: Affordable and Clean Energy | |
| dc.subject | process automation | |
| dc.subject | in-Pipe turbine | |
| dc.subject | solenoid valve | |
| dc.subject | self-Sufficient system | |
| dc.subject | TA1-2040 | |
| dc.subject | CFD | |
| dc.subject | Engineering (General). Civil engineering (General) | |
| dc.subject | flow control | |
| dc.title | Evaluation of in-pipe turbine performance for turbo solenoid valve system | |
| dc.type | Article | |
| dspace.entity.type | Publication |