Yayın:
Are standard wastewater treatment plant design methods suitable for any municipal wastewater?

Yükleniyor...
Küçük Resim

Kurum Yazarları

Item type:Araştırmacı/Yazar,
İnsel, Hayrettin Güçlü
Prof. Dr.
Item type:Araştırmacı/Yazar,
Güneş, Gürbüz
Profesor
Item type:Araştırmacı/Yazar,
Çokgör, Emine
Profesor

Danışman

Bölüm / Program

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

IWA Publishing

Türü

Araştırma Projeleri

Akademik Birimler

Dergi Sayısı

Özet

The design and operational parameters of an activated sludge system were analyzed treating the municipal wastewaters in Istanbul. The design methods of ATV131, Metcalf & Eddy together with model simulations were compared with actual plant operational data. The activated sludge model parameters were determined using 3-month dynamic data for the biological nutrient removal plant. The ATV131 method yielded closer sludge production, total oxygen requirement and effluent nitrogen levels to the real plant after adopting correct influent chemical oxygen demand (COD) fractionation. The enhanced biological phosphorus removal (EBPR) could not easily be predicted with ATV131 method due to low volatile fatty acids (VFA) potential.

Tanım

Dergi veya Seri

Water Science and Technology

ISSN

0273-1223

ISBN

Haklar

OPEN

Anahtar Kelimeler

Biological Oxygen Demand Analysis, Sewage, Fatty Acids, Volatile, Waste Disposal, Fluid

Alıntı

Koleksiyonlar

Onay

Gözden geçir

Tamamlayıcı Bilgiler

Referans Gösteren

Related Patent

Related Goal

4
Görüntülenme
0
İndirme
Altmetric
Dimensions
PlumX Metrikleri
BIP! Indicators
Google Scholar
Scholar'da Ara ↗