Publication: Effects of Loading Rate and Duration on Axial Behavior of Concrete Confined by Fiber-Reinforced Polymer Sheets
Loading...
Date
Authors
Advisor
Journal Title
Journal ISSN
Volume Title
Publisher
American Society of Civil Engineers (ASCE)
Type
Abstract
In this study, 18 concrete cylinder specimens were tested either under uniaxial compression at different loading rates or exposed to sustained axial stresses after being jacketed externally with carbon-fiber-reinforced polymer (CFRP) sheets. The specimens were cast using medium strength concrete. All the specimens had identical dimensions and level of confinement. Loading rate and applied sustained stress level were the main test parameters. Applied loading rate varied between 0.0002 and 0.04 strain/min. Four stress levels between 0.52 and 0.85 f cc ′ (0.90 and 1.46 f co ′ ) were used in short-term creep tests. Test results showed that the stress-strain behavior of CFRP confined concrete was influenced by the change in loading rate, and CFRP confinement provided considerable increase in the creep performance of concrete. The strength enhancement was more pronounced for specimens loaded at higher strain rates, while specimens loaded at slower strain rates exhibited better deformability. Results obtained fr...
Description
Journal or Series
Journal of Composites for Construction
ISSN
1090-0268