Yayın:
Effects of internal irreversibility and heat leakage on the finite time thermoeconomic performance of refrigerators and heat pumps

dc.contributor.authorYilmaz, Tamer
dc.contributor.authorŞahi̇n, Bahri
dc.contributor.authorKodal, Ali
dc.date.accessioned2026-01-26T00:20:50Z
dc.date.issued2000-04-01
dc.description.abstractBy using finite time thermodynamic theory, a performance analysis based on the thermoeconomic criterion has been performed for an irreversible refrigerator and a heat pump. The thermoeconomic objective function is defined as the cooling load for the refrigerator and the heating load for the heat pump per unit total cost. The optimal performances and design parameters which maximize the objective functions are investigated. The design parameters under the optimal conditions have been derived analytically, and then, the effects of internal irreversibility, heat leakage and the economical parameter on the global and optimal performances have been discussed.
dc.description.urihttps://doi.org/10.1016/s0196-8904(99)00129-6
dc.description.urihttps://dx.doi.org/10.1016/s0196-8904(99)00129-6
dc.description.urihttps://avesis.yildiz.edu.tr/publication/details/b6f44d6c-cf28-4414-b4f9-7ce2beb726ff/oai
dc.identifier.doi10.1016/s0196-8904(99)00129-6
dc.identifier.endpage619
dc.identifier.issn0196-8904
dc.identifier.openairedoi_dedup___::ad02b6189a7cec808b273cd7ecf2b00d
dc.identifier.orcid0000-0001-9207-7731
dc.identifier.orcid0000-0002-3885-9588
dc.identifier.startpage607
dc.identifier.urihttps://hdl.handle.net/11527/54148
dc.identifier.volume41
dc.language.isoeng
dc.publisherElsevier BV
dc.relation.ispartofEnergy Conversion and Management
dc.rightsCLOSED
dc.sdg.typeGoal 7: Affordable and Clean Energy
dc.titleEffects of internal irreversibility and heat leakage on the finite time thermoeconomic performance of refrigerators and heat pumps
dc.typeArticle
dspace.entity.typePublication

Dosyalar

Koleksiyonlar