Yayın:
A detailed GIS based assessment of bioenergy plant locations using location-allocation algorithm

Yükleniyor...
Küçük Resim

Kurum Yazarları

Danışman

Bölüm / Program

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Elsevier BV

Türü

Araştırma Projeleri

Akademik Birimler

Dergi Sayısı

Özet

<p>Logistics plays a crucial role in the operation and planning of biogas plants. To achieve better economic returns and develop effective waste management strategies, optimizing the location of these plants is essential. Geographical Information Systems (GIS) have proven to be a valuable tool for evaluating plant locations and logistics. In this study, a detailed GIS-based mapping of energy sources and plant location optimization was conducted for the Meric-Ergene basin in Northwestern Turkey. This region is well-known for its intensive livestock activities; cattle manure and sewage sludge are considered as energy sources. The model used in this study takes into account various factors, including infrastructural, environmental, and regulatory constraints, transportation distances and costs. Three different scenarios were developed for installed capacities of 5 MW, 1.7 MW, and 1 MW. An energy density map was generated using kernel density interpolation, and the plant locations were determined by solving the location-allocation problem for each scenario. The total energy potential of the study area resulting from cattle manure and sewage sludge was found to be 23.6 MWh per hour. To utilize all the energy sources considered in the study, five plants with a capacity of 5 MW should be constructed. However, when the installed capacity was reduced to 1.7 MW, the number of required plants increased to 14, and for an installed capacity of 1 MW, 24 plants were necessary. The model output revealed that transportation costs increased more than tenfold when installed capacity was increased from 1 MW to 5 MW. Along with transportation costs, the maximum transportation distance should be increased from 40 km to 100 km to cover all energy sources for 5 MW plants. Therefore, it was concluded that installed capacities of 1.7 MW and 1 MW were more suitable than that of 5 MW, considering economic and environmental concerns.</p>

Tanım

Dergi veya Seri

Applied Energy

ISSN

0306-2619

ISBN

Haklar

OPEN

Anahtar Kelimeler

Alıntı

Koleksiyonlar

Onay

Gözden geçir

Tamamlayıcı Bilgiler

Referans Gösteren

Related Patent

Related Goal

2
Görüntülenme
0
İndirme
Altmetric
Dimensions
PlumX Metrikleri
BIP! Indicators
Google Scholar
Scholar'da Ara ↗