Yayın:
Multiclass Classification of Hepatic Anomalies with Dielectric Properties: From Phantom Materials to Rat Hepatic Tissues

Yükleniyor...
Küçük Resim

Kurum Yazarları

Item type:Araştırmacı/Yazar,
Yılmaz, Abdolsaheb Tuba
Doç. Dr.

Danışman

Bölüm / Program

Electronics and Communication Engineering

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

MDPI AG

Türü

Araştırma Projeleri

Akademik Birimler

Dergi Sayısı

Özet

Open-ended coaxial probes can be used as tissue characterization devices. However, the technique suffers from a high error rate. To improve this technology, there is a need to decrease the measurement error which is reported to be more than 30% for an in vivo measurement setting. This work investigates the machine learning (ML) algorithms’ ability to decrease the measurement error of open-ended coaxial probe techniques to enable tissue characterization devices. To explore the potential of this technique as a tissue characterization device, performances of multiclass ML algorithms on collected in vivo rat hepatic tissue and phantom dielectric property data were evaluated. Phantoms were used for investigating the potential of proliferating the data set due to difficulty of in vivo data collection from tissues. The dielectric property measurements were collected from 16 rats with hepatic anomalies, 8 rats with healthy hepatic tissues, and in house phantoms. Three ML algorithms, k-nearest neighbors (kNN), logistic regression (LR), and random forests (RF) were used to classify the collected data. The best performance for the classification of hepatic tissues was obtained with 76% accuracy using the LR algorithm. The LR algorithm performed classification with over 98% accuracy within the phantom data and the model generalized to in vivo dielectric property data with 48% accuracy. These findings indicate first, linear models, such as logistic regression, perform better on dielectric property data sets. Second, ML models fitted to the data collected from phantom materials can partly generalize to in vivo dielectric property data due to the discrepancy between dielectric property variability.

Tanım

Dergi veya Seri

Sensors

ISSN

ISBN

Haklar

OPEN

Anahtar Kelimeler

Liver Cirrhosis, TP1-1185, Article, Machine Learning, Animals, Rats, Wistar, logistic regression (LR), logistic regression (lr), hepatic malignancies, Phantoms, Imaging, Chemical technology, Equipment Design, random forests (RF), random forests (rf), Electrophysiological Phenomena, Rats, in vivo dielectric properties, Electrophysiology, k-nearest neighbors (kNN), machine learning, Logistic Models, Liver, k-nearest neighbors (knn), Female, Algorithms, liver phantoms

Alıntı

Yilmaz, T. (2020). Multiclass Classification of Hepatic Anomalies with Dielectric Properties: From Phantom Materials to Rat Hepatic Tissues. Sensors (14248220), 20(2), 1–13. https://doi.org/10.3390/s20020530

Koleksiyonlar

Onay

Gözden geçir

Tamamlayıcı Bilgiler

Referans Gösteren

Related Patent

Related Goal

2
Görüntülenme
3
İndirme
Altmetric
Dimensions
PlumX Metrikleri
BIP! Indicators
Google Scholar
Scholar'da Ara ↗