Yayın:
Occurrence of the Persistent Antimicrobial Triclosan in Microwave Pretreated and Anaerobically Digested Municipal Sludges under Various Process Conditions

dc.contributor.authorKor-Bicakci, Gokce
dc.contributor.authorAbbott, Timothy
dc.contributor.authorUbay-Cokgor, Emine
dc.contributor.authorEskicioglu, Cigdem
dc.contributor.ituauthorÇokgör, Emine
dc.date.accessioned2026-01-24T17:17:59Z
dc.date.issued2020-01-12
dc.description.abstractTreatment of emerging contaminants, such as antimicrobials, has become a priority topic for environmental protection. As a persistent, toxic, and bioaccumulative antimicrobial, the accumulation of triclosan (TCS) in wastewater sludge is creating a potential risk to human and ecosystem health via the agricultural use of biosolids. The impact of microwave (MW) pretreatment on TCS levels in municipal sludge is unknown. This study, for the first time, evaluated how MW pretreatment (80 and 160 °C) itself and together with anaerobic digestion (AD) under various sludge retention times (SRTs: 20, 12, and 6 days) and temperatures (35 and 55 °C) can affect the levels of TCS in municipal sludge. TCS and its potential transformation products were analyzed with ultra-high-performance liquid chromatography and tandem mass spectrometry. Significantly higher TCS concentrations were detected in sludge sampled from the plant in colder compared to those in warmer temperatures. MW temperature did not have a discernible impact on TCS reduction from undigested sludge. However, AD studies indicated that compared to controls (no pretreatment), MW irradiation could make TCS more amenable to biodegradation (up to 46%), especially at the elevated pretreatment and digester temperatures. At different SRTs studied, TCS levels in the thermophilic digesters were considerably lower than that of in the mesophilic digesters.
dc.description.urihttps://doi.org/10.3390/molecules25020310
dc.description.urihttps://www.mdpi.com/1420-3049/25/2/310/pdf
dc.description.urihttps://dx.doi.org/10.14288/1.0388487
dc.description.urihttps://pubmed.ncbi.nlm.nih.gov/31940954
dc.description.urihttp://dx.doi.org/10.3390/molecules25020310
dc.description.urihttps://doaj.org/article/6b67325f13984c498d0e85ba6670f683
dc.description.urihttps://dx.doi.org/10.3390/molecules25020310
dc.description.urihttps://aperta.ulakbim.gov.tr/record/11017
dc.identifier.doi10.3390/molecules25020310
dc.identifier.eissn1420-3049
dc.identifier.openairedoi_dedup___::1afaaea372a5266adca47815217ffb07
dc.identifier.orcid0000-0001-8083-1186
dc.identifier.orcid0000-0002-4904-6056
dc.identifier.orcid0000-0002-7673-134x
dc.identifier.startpage310
dc.identifier.urihttps://hdl.handle.net/11527/36264
dc.identifier.volume25
dc.language.isoeng
dc.publisherMDPI AG
dc.relation.ispartofMolecules
dc.rightsOPEN
dc.sdg.typeGoal 7: Affordable and Clean Energy
dc.sdg.typeGoal 12: Responsible Consumption and Production
dc.sdg.typeGoal 6: Clean Water and Sanitation
dc.sdg.typeGoal 13: Climate Action
dc.subjectanaerobic digestion
dc.subjectmunicipal sludge
dc.subjectHot Temperature
dc.subjectmicrowave
dc.subjecttriclosan
dc.subjectOrganic chemistry
dc.subjectWaste Disposal, Fluid
dc.subjectArticle
dc.subjectQD241-441
dc.subjectTandem Mass Spectrometry
dc.subjecttandem mass spectrometry
dc.subjectHumans
dc.subjectantimicrobial disinfectants
dc.subjectAnaerobiosis
dc.subjectMicrowaves
dc.subjectChromatography, High Pressure Liquid
dc.subjectpersonal care products
dc.subjectSewage
dc.subjectthermal pretreatment
dc.subjectTriclosan
dc.subjectBiodegradation, Environmental
dc.subjectultra-high performance liquid chromatography
dc.subjectcontaminants of emerging concern
dc.subjectAnti-Infective Agents, Local
dc.subjectEnvironmental Pollutants
dc.titleOccurrence of the Persistent Antimicrobial Triclosan in Microwave Pretreated and Anaerobically Digested Municipal Sludges under Various Process Conditions