Publication: Magnetic actuator driver system for laser scanning capsule endoscopy
Loading...
Date
Advisor
Journal Title
Journal ISSN
Volume Title
Publisher
Elsevier bv
Type
Abstract
This paper focuses on designing and implementing a power and area-efficient magnetic actuator driver interface integrated circuit for laser scanning capsule endoscopy. The proposed system contains a 3D-printed focus- adjusting actuator embarking a lens, multiple magnets, an external coil, battery, laser, and actuator driver integrated circuit with off-chip components. The actuator features multiple pantograph springs connected to the lens, as well as multiple magnets, enabling precise focusing capability through electromagnetic actuation. A magnetic actuator driver integrated circuit implemented in a commercial 180 nm CMOS process drives the coil at 32 Hz, which is the mechanical resonance frequency of the actuator. A novel control methodology for the driver has been devised, aimed at enhancing driving efficiency and mitigating total harmonic distortion. Simulations and measurements substantiate that the actuator can induce a 3.22 mm focal point displacement while the driver circuit delivers 9.62 mA (RMS) current to the 7.7 mH coil. Under these conditions, the system exhibits an aggregate power consumption of 11.48 mW, thereby achieving a power efficiency of 85.5%.
Description
Journal or Series
Aeu - international journal of electronics and communications
ISSN
1434-8411
ISBN
Rights
closedAccess
Keywords
Laser scanning, 3d printed focus actuator, Capsule endoscopy, Magnetic actuator driver, Amplitude and harmonic control