Publication:
Finite element model of the Jefferson fracture: comparison with a cadaver model

Loading...
Thumbnail Image

Institution Authors

Item type:Person,
Bozdağ, Süreyya Ergün
Öğretim Görevlisi Dr.

Advisor

Department

Journal Title

Journal ISSN

Volume Title

Publisher

Springer Science and Business Media LLC

Research Projects

Organizational Units

Journal Issue

Abstract

This study tries to explain the reason why the Jefferson fracture is a burst fracture, using two different biomechanical models: a finite element model (FEM) and a cadaver model used to determine strain distribution in C1 during axial static compressive loading. For the FEM model, a three-dimensional model of C1 was obtained from a 29-year-old healthy human, using axial CT scans with intervals of 1.0 mm. The mesh model was composed of 8200 four-noded isoparametric tetrahedrons and 37,400 solid elements. The material properties of the cortical bone of the vertebra were assessed according to the previous literature and were assumed to be linear isotropic and homogeneous for all elements. Axial static compressive loads were applied at between 200 and 1200 N. The strain and stress (maximum shear and von Mises) analyses were determined on the clinically relevant fracture lines of anterior and posterior arches. The results of the FEM were compared with a cadaver model. The latter comprised the C1 bone of a cadaver placed in a methylmethacrylate foam. Axial static compressive loads between 200 and 1200 N were applied by an electrohydraulic testing machine. Strain values were measured using strain gauges, which were cemented to the bone where the clinically relevant fracture lines of the anterior and posterior arches were located. As a result, compressive strain was observed on the outer surface of the anterior arch and inferior surface of the posterior arch. In addition, there was tensile strain on the inner surface of the anterior arch and superior surface of the posterior arch. The strain values obtained from the two experimental models showed similar trends. The FEM analysis revealed that maximum strain changes occurred where the maximum shear and von Mises stresses were concentrated. The changes in the C1 strain and stress values during static axial loading biomechanically prove that the Jefferson fracture is a burst fracture.

Description

Journal or Series

European Spine Journal

ISSN

0940-6719

ISBN

Rights

OPEN

Keywords

Adult, Finite Element Analysis, Photography, Humans, Spinal Fractures, Stress, Mechanical, Cervical Atlas, Biomechanical Phenomena

Citation

Collections

Endorsement

Review

Supplemented By

Referenced By

Related Patent

Related Goal

4
Görüntülenme
0
İndirme
Altmetric
Dimensions
PlumX Metrikleri
BIP! Indicators
Google Scholar
Scholar'da Ara ↗