Publication:
Seismic Behavior of Repaired and Externally FRP-Jacketed Short Columns Built with Extremely Low-Strength Concrete

dc.contributor.authorBedirhanoglu, Idris
dc.contributor.authorIlki, Alper
dc.contributor.authorTriantafillou, Thanasis C.
dc.date.accessioned2026-01-26T06:49:57Z
dc.date.issued2022-02-01
dc.description.abstractShort columns with deficiencies of low-strength concrete and large spacing of transverse reinforcement are quite common in construction practice in many developing countries in seismically active regions. Therefore, it is important to retrofit this type of column to avoid negative consequences in the case of severe damage. External fiber-reinforced polymer (FRP) jacketing is one of the most practical methods to retrofit reinforced concrete (RC) frame members against shear actions. However, knowledge of the seismic behavior of FRP-retrofitted RC short columns is still limited. Thus, the aim of this study was to investigate the seismic response of FRP-retrofitted low-strength RC short columns with and without predamage through the testing of 11 short column specimens representing old and deficient RC buildings. Accordingly, the results of a research program on the seismic behavior of such columns and on their repair and FRP retrofitting, covering experimental and analytical phases, are presented. In the experimental phase, test results obtained for short columns, FRP-retrofitted short columns, and repaired and retrofitted short columns are documented. Test results provide important knowledge about the effects of extremely low-strength concrete, and of different levels of predamage on the behavior of FRP-retrofitted substandard short columns. In the analytical phase, the performance of relevant design documents in predicting the shear strength of such columns retrofitted with FRP jacketing was tested through the comparison of predicted and experimental results.
dc.description.abstractWOS:000730390000001
dc.description.urihttps://doi.org/10.1061/(asce)cc.1943-5614.0001179
dc.description.urihttps://hdl.handle.net/11468/8834
dc.description.urihttps://aperta.ulakbim.gov.tr/record/254829
dc.identifier.doi10.1061/(asce)cc.1943-5614.0001179
dc.identifier.eissn1943-5614
dc.identifier.issn1090-0268
dc.identifier.openairedoi_dedup___::f209062c214bb37bf1c22e82e391692f
dc.identifier.orcid0000-0001-6852-3041
dc.identifier.orcid0000-0003-0263-3955
dc.identifier.urihttps://hdl.handle.net/11527/63130
dc.identifier.volume26
dc.language.isoeng
dc.publisherAmerican Society of Civil Engineers (ASCE)
dc.relation.ispartofJournal of Composites for Construction
dc.rightsOPEN
dc.subjectReinforced concrete
dc.subjectFiber-reinforced polymer (FRP)
dc.subjectShort columns
dc.subjectStrengthening
dc.subjectShear
dc.subjectPredamage
dc.subjectGlass
dc.subjectCarbon
dc.titleSeismic Behavior of Repaired and Externally FRP-Jacketed Short Columns Built with Extremely Low-Strength Concrete
dc.typeArticle
dspace.entity.typePublication

Files

Collections