Abstract

AbstractComposite materials have made far‐reaching changes in the space industry since they have been adopted into the structural and thermal control subsystems of space vehicles because of their several multi‐functions, including being lightweight as well as having advanced mechanical and thermal properties. The use of composites as space radiation shielding materials is also one of the most crucial applications because space radiation is a major impediment for current and future deep‐space missions. Investigation of carbon fiber composites with a diverse array of element and nanoparticle reinforcements has revealed their potential as an alternative to conventional radiation shielding materials in space. This study focused on the alleviation of gamma‐ray and neutron radiation by carbon fiber/epoxy composites incorporated with various weight ratios of carbon nanotube (CNT) and boron nitride (BN) nanoparticles. A narrow beam geometry setup was used for gamma radiation tests with a Cs‐137 gamma‐ray source, while neutron radiation experiments were conducted in a neutron howitzer with a 239Pu‐Be neutron source. Six groups of specimens, namely, pure carbon fiber/epoxy, 0.5 wt% CNT, 0.5 wt% BN, 0.5 wt% CNT + 0.5 wt% BN, 1 wt% CNT + 1 wt% BN, and 2 wt% BN, were examined against these two types of radiation. Results have indicated that the 2 wt% BN specimen showed the best attenuation properties against both gamma‐ray and neutron radiation among all tested specimens; furthermore, it was almost three times more effective against neutron radiation than against gamma‐ray radiation.Highlights Varying weight ratios of CNT and BN nanoparticles used for radiation shielding. A Cs‐137 gamma‐ray source used in narrow beam geometry. Neutron radiation studies were conducted in a 239Pu‐Be neutron howitzer. The 2 wt% BN sample showed the best attenuation against gamma‐ray and neutron radiation. It resulted in an HVL of 6.86 cm for gamma‐ray radiation and 2.13 cm for neutron radiation.

Description

Journal or Series

Polymer Composites

ISSN

0272-8397

ISBN

Rights

OPEN

Keywords

Polyethylene

Citation

Collections

Endorsement

Review

Supplemented By

Referenced By

Related Patent

Related Goal

3
Görüntülenme
0
İndirme
Altmetric
Dimensions
PlumX Metrikleri
BIP! Indicators
Google Scholar
Scholar'da Ara ↗