Abstract

The tracking of radiation dose is a fundamental concept for the safe operation of nuclear instruments, and this concept is a multi-task challenge in the case of neutron sources since not only the neutron emissions from the main radioactive source but also the neutron capture gamma-rays as well as the gamma-rays from the inelastic neutron scattering make contribution to the total dose received by the facility personnel. The present study is devoted to the assessment of the equivalent dose rates on the surface of a Nuclear-Chicago NH3 neutron howitzer with a 5-Ci 239Pu-Be neutron source by means of Monte Carlo simulations. The 5-Ci 239Pu-Be neutron source is mounted within a vertical aluminum channel at the center of the neutron howitzer, and we use the axial symmetry of the aluminum drum filled with an ordinary paraffin without any potent neutron absorber such as boron or cadmium. We utilise the ICRP-21 flux-to-dose rate conversion factors and we track the neutron and photon equivalent dose rates on the lateral and top surfaces including the outlets of the vertical and horizontal irradiation channels by the aid of point detectors in the MCNP5 code. From the results over a number of sub-regions on the semi-cylindrical drum of the Nuclear-Chicago NH3 neutron howitzer, we show that the outlets of both the vertical and horizontal irradiation channels deliver approximately the same level of equivalent dose rates, and the maximum equivalent dose rates for neutrons and photons on the lateral surface are obtained at the spatial coordinates aligned with the location of the 5-Ci 239Pu-Be neutron source, whereas the periphery around the source channel on the top surface of the neutron howitzer constitutes the highest level of equivalent dose rates among the tracked locations.
11 pages, 12 figures, 49th Annual Meeting on Nuclear Technology (AMNT 2018)

Description

Journal or Series

ISSN

ISBN

Rights

OPEN

Keywords

FOS: Physical sciences, Medical Physics (physics.med-ph), Physics - Medical Physics

Citation

Collections

Endorsement

Review

Supplemented By

Referenced By

Related Patent

Related Goal

2
Görüntülenme
0
İndirme
Altmetric
Dimensions
PlumX Metrikleri
BIP! Indicators
Google Scholar
Scholar'da Ara ↗