Publication:
Electrode modification based on “click electrochemistry” between terminal-alkynyl substituted cobalt phthalocyanine and 4-azidoaniline

dc.contributor.authorIpek, Yeliz
dc.contributor.authorDincer, Hatice
dc.contributor.authorKoca, Atif
dc.date.accessioned2026-01-24T23:39:51Z
dc.date.issued2014-03-01
dc.description.abstractAbstract A new electrochemical sensor electrode was constructed with a new electrode modification technique, “click electrochemistry” (CEC) based on a functional cobalt phthalocyanine. In this newly constructed modified electrode (GCE/PANI-N 3 /TA-CoPc (CEC)), a terminal-alkynyl (TA) substituted cobalt phthalocyanine (CoPc-TA) was electrochemically bonded to the azido end of electro-polymerized 4-azidoaniline (PANI-N 3 ), which was electropolymerized on the GCE electrochemically previously. GCE/PANI-N 3 /TA-CoPc (CEC) electrode was characterized with voltammetric, electrochemical impedance spectroscopy (EIS), UV–vis spectroscopy, and scanning electron microscopy (SEM) techniques. GCE/PANI-N 3 /TA-CoPc electrode gave three redox couples assigned to the CoPc and PANI in nonaqueous and aqueous electrolyte systems, which is a desired factor for the application of a modified electrode in various electrochemical applications such as electrocatalytic and electrosensing fields. Pesticide sensing responses of GCE/ PANI-N 3 /TA-CoPc (CEC) electrode were tested with SWV method for usability as an electrochemical pesticide sensor for eserine. Basic sensor parameters, calibration lines, and detection limits (LOD) of GCE/ PANI-N 3 /TA-CoPc (CEC) electrode were derived from SWV responses of the electrode. Amperometric sensing analyses of SVW responses of the electrode give a linear range between 1.56 × 10 −7 and 2.45 × 10 −6  mol dm −3 eserine with a sensitivity of 1.15 A dm 3  mol −3 and LOD of 1.75 × 10 −7  mol dm −3 .
dc.description.urihttps://doi.org/10.1016/j.snb.2013.12.031
dc.description.urihttps://dx.doi.org/10.1016/j.snb.2013.12.031
dc.description.urihttps://aperta.ulakbim.gov.tr/record/65299
dc.identifier.doi10.1016/j.snb.2013.12.031
dc.identifier.endpage837
dc.identifier.issn0925-4005
dc.identifier.openairedoi_dedup___::363b279b2c0d3ac774c0a66f7443e189
dc.identifier.orcid0000-0003-0141-5817
dc.identifier.startpage830
dc.identifier.urihttps://hdl.handle.net/11527/39647
dc.identifier.volume193
dc.language.isoeng
dc.publisherElsevier BV
dc.relation.ispartofSensors and Actuators B: Chemical
dc.rightsOPEN
dc.sdg.typeGoal 3: Good Health and Well-being
dc.titleElectrode modification based on “click electrochemistry” between terminal-alkynyl substituted cobalt phthalocyanine and 4-azidoaniline
dc.typeArticle
dspace.entity.typePublication

Files

Collections