Publication: Electrode modification based on “click electrochemistry” between terminal-alkynyl substituted cobalt phthalocyanine and 4-azidoaniline
| dc.contributor.author | Ipek, Yeliz | |
| dc.contributor.author | Dincer, Hatice | |
| dc.contributor.author | Koca, Atif | |
| dc.date.accessioned | 2026-01-24T23:39:51Z | |
| dc.date.issued | 2014-03-01 | |
| dc.description.abstract | Abstract A new electrochemical sensor electrode was constructed with a new electrode modification technique, “click electrochemistry” (CEC) based on a functional cobalt phthalocyanine. In this newly constructed modified electrode (GCE/PANI-N 3 /TA-CoPc (CEC)), a terminal-alkynyl (TA) substituted cobalt phthalocyanine (CoPc-TA) was electrochemically bonded to the azido end of electro-polymerized 4-azidoaniline (PANI-N 3 ), which was electropolymerized on the GCE electrochemically previously. GCE/PANI-N 3 /TA-CoPc (CEC) electrode was characterized with voltammetric, electrochemical impedance spectroscopy (EIS), UV–vis spectroscopy, and scanning electron microscopy (SEM) techniques. GCE/PANI-N 3 /TA-CoPc electrode gave three redox couples assigned to the CoPc and PANI in nonaqueous and aqueous electrolyte systems, which is a desired factor for the application of a modified electrode in various electrochemical applications such as electrocatalytic and electrosensing fields. Pesticide sensing responses of GCE/ PANI-N 3 /TA-CoPc (CEC) electrode were tested with SWV method for usability as an electrochemical pesticide sensor for eserine. Basic sensor parameters, calibration lines, and detection limits (LOD) of GCE/ PANI-N 3 /TA-CoPc (CEC) electrode were derived from SWV responses of the electrode. Amperometric sensing analyses of SVW responses of the electrode give a linear range between 1.56 × 10 −7 and 2.45 × 10 −6 mol dm −3 eserine with a sensitivity of 1.15 A dm 3 mol −3 and LOD of 1.75 × 10 −7 mol dm −3 . | |
| dc.description.uri | https://doi.org/10.1016/j.snb.2013.12.031 | |
| dc.description.uri | https://dx.doi.org/10.1016/j.snb.2013.12.031 | |
| dc.description.uri | https://aperta.ulakbim.gov.tr/record/65299 | |
| dc.identifier.doi | 10.1016/j.snb.2013.12.031 | |
| dc.identifier.endpage | 837 | |
| dc.identifier.issn | 0925-4005 | |
| dc.identifier.openaire | doi_dedup___::363b279b2c0d3ac774c0a66f7443e189 | |
| dc.identifier.orcid | 0000-0003-0141-5817 | |
| dc.identifier.startpage | 830 | |
| dc.identifier.uri | https://hdl.handle.net/11527/39647 | |
| dc.identifier.volume | 193 | |
| dc.language.iso | eng | |
| dc.publisher | Elsevier BV | |
| dc.relation.ispartof | Sensors and Actuators B: Chemical | |
| dc.rights | OPEN | |
| dc.sdg.type | Goal 3: Good Health and Well-being | |
| dc.title | Electrode modification based on “click electrochemistry” between terminal-alkynyl substituted cobalt phthalocyanine and 4-azidoaniline | |
| dc.type | Article | |
| dspace.entity.type | Publication |