Publication: A Realizability Test as Applied on the Generated Source/Load-Pull Data
Loading...
Date
Advisor
Department
Journal Title
Journal ISSN
Volume Title
Publisher
IEEE
Type
Abstract
Generation of proper source/load pull impedances for a selected active device is essential to design an RF power amplifier for optimum gain and power added efficiency. As they are obtained, these impedances may not be realizable network functions over the desired frequency band to yield the input and the output matching networks for the amplifier. Therefore, in this paper, we introduce a useful method to test if the generated source and load pull data are realizable. The proposed technique is employed to test the given source and load pull impedance data obtained from the 45W-GaN power transistor of Wolfspeed CG2H40045 over 0.8-3.8 GHz bandwidth.
Description
Journal or Series
2022 Microwave Mediterranean Symposium (MMS)
ISSN
ISBN
Rights
OPEN
Keywords
Immittance Realizability Conditions, Foster Functions, Minimum Functions, GaN Transistor, Broadband Matching, Positive Real Functions, Gan Power-Amplifier, Real Frequency Techniques, Broadband Power Amplifier