Publication:
Single Vs. Double Input Interval Type-2 Fuzzy PID Controllers: Which One is Better?

Loading...
Thumbnail Image

Advisor

Journal Title

Journal ISSN

Volume Title

Publisher

IEEE

Research Projects

Organizational Units

Journal Issue

Abstract

In this paper, we will analyze and present systematic design approaches for the most commonly employed Interval Type-2 (IT2) Fuzzy PID (FPID) controllers which are the Single input IT2 (SIT2) and Double IT2 (DIT2) FPID controllers. We will firstly start with presenting the general structure of the IT2-FPID controllers and then present internal model control based tuning approaches to calculate the scaling factors of the IT2-FPID controllers. It will be shown that, by simply tuning the Footprint of Uncertainty parameters, how to construct aggressive and smooth control curves for SIT2-FPID controllers while aggressive and smooth control surfaces for DIT2-FPID controllers. Finally, we will present real world experiments using a tricycle that will act as a platform to validate the control systems. The comparative experimental results will show that the real-time tracking control performance of both the SIT2-FPID and DIT2-FPID control structure is better in the presence of noise and unmodelled dynamics in comparison with their Type-1 fuzzy and conventional counterparts. We will also try to address the question "Which IT2-FPID controller is better?" by taking account the design simplicity and control system performance.