Publication: Passive thermographic detection of moisture problems in façades with adhered ceramic cladding
Loading...
Date
Advisor
Department
Journal Title
Journal ISSN
Volume Title
Publisher
Elsevier BV
Type
Abstract
Abstract Adhered ceramic facade claddings are susceptible to defects, of which increasing moisture content is one of the causes, and infrared thermography can be used to detect this phenomenon before visible signs occur. Moisture detection procedures by thermography are not standardised. Research based on in situ inspections was undertaken to adapt present procedures for use on glazed ceramic claddings. In this article we discuss the findings of that research and the results of numerical simulations performed afterwards. Passive thermography using solar heat gain was found to have potential to detect moisture content change in adhered ceramic claddings as a preliminary inspection technique.
Description
Journal or Series
Construction and Building Materials
ISSN
0950-0618
ISBN
Rights
CLOSED