Publication:
The Fate of the Cyanotoxin Dihydroanatoxin-a in Drinking Water Treatment Processes

Loading...
Thumbnail Image

Institution Authors

Advisor

Department

Journal Title

Journal ISSN

Volume Title

Publisher

MDPI AG

Research Projects

Organizational Units

Journal Issue

Abstract

Only recently has the cyanotoxin dihydroanatoxin-a (dhATX-a) been detected more frequently in different surface waters, some of which are used for supplying drinking water. As data about the fate of dhATX-a in drinking water treatment processes are still scarce, the present study investigated the behavior of dhATX-a in different water treatment steps: slow sand filtration, flocculation, adsorption onto activated carbon, ozonation and chlorination. The almost complete removal (>95%) of dhATX-a was observed in sand columns simulating slow sand filtration without showing a long adaptation phase. The results further indicate that dhATX-a can be removed using powdered activated carbon at dosages of 50 mg/L with removal rates between 75 and 93% and also by using ozonation with dosages above 1 mg/L at a concentration of ca. 4.5 mg/L background organic carbon. In contrast, no elimination of dhATX-a was observed in flocculation and chlorination experiments.