<link rel="stylesheet" href="styles.cf390c6bfbe7555f.css">

Publication:
A real time resonance detection and mitigation method for shunt active power filters

Loading...
Thumbnail Image

Institution Authors

Journal Title

Journal ISSN

Volume Title

Publisher

Graduate School

Research Projects

Organizational Units

Journal Issue

Abstract

Maintaining high power quality is a growing challenge in modern power systems due to the proliferation of nonlinear and dynamic loads. Shunt active power filters (SAPFs) are effective power electronic devices for mitigating harmonic distortion, compensating reactive power, and reducing the impact of nonlinearity on the grid. However, the use of inductor capacitor inductor (LCL) filters in SAPFs introduces a tendency toward resonance, especially when interacting with grid impedance and external capacitive elements. This often results in parallel resonance, degrading performance and threatening system stability. This thesis introduces a real time, adaptive control architecture designed to detect and suppress such resonances without interrupting the standard harmonic compensation function of the SAPF. Unlike conventional fixed parameter techniques such as passive damping or active virtual impedance the proposed method uses a dynamic and decentralized approach. It continuously monitors grid conditions and adapts the filter's behavior using a novel resonance detection metric. Instead of relying on total harmonic distortion (THD), which can be unreliable under high background distortion, resonance is detected through apparent harmonic power derived from simultaneous high voltage and current magnitudes at a given harmonic order. This power based metric is weighted by frequency to prioritize higher order harmonics more susceptible to resonance. Upon detection, a Perturb and Observe (P&O) algorithm individually tunes the compensation coefficient for each affected harmonic. This iterative process increases or decreases compensation strength based on the system's response, converging to an optimal suppression level. The method enables self optimization for each harmonic channel independently. The system was implemented using a digital signal processor (DSP) and a field programmable gate array (FPGA). Real time fast fourier transform (FFT) analysis was performed on the FPGA, while the DSP managed decision logic and coefficient adjustments within pulse width modulation (PWM) cycles. Experimental validation on a 100 kilo volt amper (kVA) three phase SAPF prototype confirmed the method's effectiveness. Under induced resonance conditions such as with added 1250 µF capacitors THD was reduced from over 190% to below 7%, restoring waveform quality and system stability. The method succeeded in suppressing resonance not only at the 11th harmonic but also at the 7th, 13th, 29th, 31st, and 35th harmonics. The proposed approach is non intrusive, hardware independent, and computationally efficient. It operates transparently alongside the active power filter (APF) control loop, requiring no suspension of normal SAPF functions. Its modular structure allows integration into multi inverter or hybrid filter systems. In summary, this thesis presents a practical, intelligent, and adaptable solution to resonance problems in SAPF systems, marking a significant advancement in the field of power quality and control.

Description

Thesis (M.Sc.) -- Istanbul Technical University, Graduate School, 2025

Journal or Series

ISSN

ISBN

Rights

Keywords

power filters, güç filtreleri, energy systems, enerji sistemleri, Shunt Active Power Filter, Şönt Aktif Güç Filtreleri

Citation

Endorsement

Review

Supplemented By

Referenced By

Related Patent

Related Goal

Google Scholar
Scholar'da Ara ↗
Bu yayında DOI yok — Altmetric/Dimensions/PlumX/BIP! rozetleri DOI gerektirir.